CALL US
920.337.0234
FSC Acquires Norcan

BOSCH
0811401200

$1,843.00

BOSCH

MATERIAL:  0811401200

Due to extremely high demand, please call 920-337-0234 for availability

Valves of type ZDC are direct operated supply pressure compensators in 2-way version.

As with all throttle cross-sections, the flow of proportional throttle valves and directional valves depends on the pressure differential Δp.

The effect of a load-compensated, electrical flow control valve results from the combination of throttle valve (measuring throttle) and pressure compensator which keeps the pressure differential Δp at the measurement throttle constant. The pressure differential is determined by the pressure compensator spring and depending on the selected design, it ranges between 8 and 25 bar.

The combination of a proportional directional valve with a pressure compensator results in the effect of a flow control valve for 2 directions. The changing load pressure is to be scanned via a shuttle valve. If pulling loads result during deceleration of mass, counterholding valves are to be provided.

01

02

03

04

05

06

07

08

09

10

Z

DC

6

X

-

1X

/

M

*

01

Sandwich plate valve

Z

02

Meter-in pressure compensator

DC

03

Size 6

6

04

Porting pattern according to DIN 24340 form A

X

05

Load compensation in channel P

P

Load compensation in channel A

A

06

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) - Size 10

1X

Pressure differential

07

8 bar

8

14 bar

14

25 bar

25

Seal material

08

NBR seals

M

09

No special version

no code

Special setting with directional valve 4WRPE

-291

Control in P on component side; supply optionally A or P; pilot pressure from B

-287

Flow in A; pilot pressure from T

-292

10

Further details in the plain text

*

For applications outside these parameters, please consult us!

allgemein

Nenngröße

6

Geräteserie

1X

Einbaulage

Any

Masse

kg

1.5

hydraulisch

Maximaler Betriebsdruck

bar

250

Maximum flow 1)

l/min

35

Druckflüssigkeitstemperaturbereich

°C

-20 … +70

Maximal zulässiger Verschmutzungsgrad der Druckflüssigkeit; Reinheitsklasse nach ISO 4406 (c) 2)

Class 20/18/15

Viskositätsbereich

mm²/s

15 … 380
1) depending on the pressure differential
2) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils and related hydrocarbons

HL, HLP, HLPD, HVLP, HVLPD

NBR

DIN 51524

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids please contact us.

There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.).

(measured with HLP46, ϑOil = 40 ±5 °C)

Flow control P → A, P → B

technical illustration-0811401200-Sandwich plate valve Porting pattern according to DIN 24340 form A Load compensation in channel P → A or P → B by installed shuttle valve 2-way version "P" Flow control in case of interaction with proportional directional valve

Flow control P → A, P → B

technical illustration-0811401200-Sandwich plate valve Porting pattern according to DIN 24340 form A Load compensation in channel P → A or P → B by installed shuttle valve 2-way version "P" Flow control in case of interaction with proportional directional valve

Type ZDC..P-2X/...-291

technical illustration-0811401200-Sandwich plate valve Porting pattern according to DIN 24340 form A Load compensation in channel P → A or P → B by installed shuttle valve 2-way version "P" Flow control in case of interaction with proportional directional valve

Type ZDC..P-2X/...-292

technical illustration-0811401200-Sandwich plate valve Porting pattern according to DIN 24340 form A Load compensation in channel P → A or P → B by installed shuttle valve 2-way version "P" Flow control in case of interaction with proportional directional valve

Type ZDC..P-2X/...-292

technical illustration-0811401200-Sandwich plate valve Porting pattern according to DIN 24340 form A Load compensation in channel P → A or P → B by installed shuttle valve 2-way version "P" Flow control in case of interaction with proportional directional valve

Dimensions in mm

technical illustration-0811401200-Sandwich plate valve Porting pattern according to DIN 24340 form A Load compensation in channel P → A or P → B by installed shuttle valve 2-way version "P" Flow control in case of interaction with proportional directional valve

component side - porting pattern according to DIN 24340 form A

plate side - porting pattern according to DIN 24340 form A

1

Name plate

2

Valve mounting bores

3

Identical seal rings for ports A, B, P, and T

Valve mounting screws (separate order)
4 hexagon socket head cap screws ISO 4762 - M5 - 10.9
Notice:
Length and tightening torque of the valve mounting screws must be calculated according to the components mounted under and over the sandwich plate valve.