BOSCH REXROTH
0811405139
BOSCH REXROTH
MATERIAL: 0811405139
SUMMARY:
Due to extremely high demand, please call 920-337-0234 for availability


01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
||||
VT- |
M |
A |
C |
A |
S |
– |
500 |
– |
1X |
/ |
V0 |
/ |
01 |
VT- |
|
02 |
M |
|
Hydraulic component |
||
03 |
Axis control |
A |
Type |
||
04 |
Controller |
C |
Control |
||
05 |
Analog |
A |
Function |
||
06 |
Position control |
S |
Serial number for types |
||
07 |
Standard variant without valve amplifier function |
500 |
08 |
Component series 10 ... 19 (10 ... 19: unchanged technical data and pin assignment) |
1X |
Customer version |
||
09 |
Catalog version |
V0 |
Option |
||
10 |
Marking variant with voltage input |
I |
Variant with current input |
Without |
General
Power supply |
nominal 24V= battery voltage 21...40V, rectified alternating voltageUeff=21...28V (single-phase, full-wave rectifier) |
|||
Current consumption, max. |
mA |
200 | ||
Signal input |
VT-MACAS-500-10/V0 |
Ucommand: ±10V, differential amplifier Ri= 100kΩ |
||
VT-MACAS-500-10/V0/l |
Iist: 4...20mA Rsh = 200Ω |
|||
Actual value signal |
VT-MACAS-500-10/V0 |
Uactual: ±10V, differential amplifier Ri= 100kΩ |
||
VT-MACAS-500-10/V0/l |
Iist: 4...20mA Rsh = 200Ω |
|||
Valve signal |
UV= ±10V (max. 10mA) or IV= 4...20mA (middle 12mA) |
|||
Compensation step |
can be switched off; effective in a range of ±4% |
|||
Enable signal |
V= |
8,5...40V | ||
Error message |
no error: 24Vnom (UB) max. 50mA error: <2V |
|||
IN POS message |
IN POS: 24Vnom (UB) max. 50mA not IN POS: <2V |
|||
Ramp ranges |
I: 0,1...1s II: 1...10s |
|||
Area adjustmentAK:AR |
min. 1:1; max. 1:4 | |||
Actual value adjustment |
Zero point: -5...10% Gain: 50...110% |
|||
Controller type |
Position: PT1 Velocity: PI |
|||
Zero point valve |
% |
±5 | ||
Special features |
–Switchable from position to velocity control –Switchable position window –Test points on front plate –Interfaces short-circuit-proof |
|||
Fastening |
Top hat rail TH35-7.5 or G rail G32 according to EN 60715 | |||
Connection |
Connectors + terminals | |||
Operating temperature |
°C |
0…+70 | ||
Storage temperature range |
°C |
-20…+70 | ||
Weight |
m |
kg |
0.38 |
For applications outside these parameters, please consult us!
Ideal development (without command value ramps)

"Overshooting“, p gain too high, → Rotate switch KP against 1

"Creeping into the position“, p gain too low, → Rotate switch KP against 16

"Vibrations“, time constant too small, → Rotate switch KT1 against 16

"Area ratio wrong"; set symmetric motion sequence by means of switch A/B

Ideal development (without command value ramps)

P gain too small, → Rotate switch KP against 16

P gain too large, → Rotate switch KP against 1

P gain correct, however following error too large, minimization of the following error by means of the I controller → Rotate switch KI until the min. following error is reached

Front plate

Block diagram with pin assignment

Wiring diagram AVPC-V

D* valve signal for valve with voltage or current interface
Wiring diagram AVPC-mA

D* valve signal for valve with voltage or current interface
Dimensions in mm