The Bosch Rexroth DR20G5-4X/100YM/12 (R900349889) is a sophisticated pilot-operated pressure reducing valve designed to modulate system pressure efficiently. This valve is particularly suitable for subplate mounting and can be optionally equipped with a check valve for applications requiring a free return flow from channel A to B. The core functionality of the DR20G5-4X/100YM/12 lies in its ability to maintain consistent pressure in the outlet channel, regulated by a spring mechanism. In its default state, the valve allows hydraulic fluid to pass from the inlet to the outlet channel unimpeded, with the main control spool being held open. The system's pressure is balanced by the force of the spring against the hydraulic pressure acting on the main control spool. When outlet channel pressure surpasses a predetermined threshold, as set by an adjustable spring, it triggers the pilot poppet to open, redirecting fluid into a spring chamber which then shifts the main control spool into a controlling position to stabilize pressure at set levels. The design includes various adjustment types such as rotary knob and sleeve with hexagon and protective cap, including options that are lockable or come with a scale for precise settings. It also features external pilot oil return via port Y and adheres to ISO porting patterns for assured compatibility and ease of integration into various hydraulic systems. With component series X; X marking, this model boasts maximum operating pressures up to bar levels, demonstrating its capability in high-pressure environments. The DR20G5-4X/100YM/12 offers reliability and precision for industries requiring accurate pressure modulation within their hydraulic systems.
The pressure valve type DR is a pilot-operated pressure reducing valve. It is used to reduce the system pressure.
It mainly consists of screw-in cartridge valve (cartridge) and housing, optionally with or without check valve (subplate mounting only).
In the rest position the valve is open. The hydraulic fluid is able to flow freely from the inlet channel via the main control spool (1) to the outlet channel. The pressure in the outlet channel is applied to the spring-loaded side of the main control spool (1) via the bore (2). At the same time, the pressure acts upon the side of the main control spool (1) that is opposite to the spring via the bores (3) and (4).
If the pressure in the outlet channel exceeds the value set at the spring (6), the pilot poppet (5) opens.
Hydraulic fluid flows from the spring-loaded side of the main control spool (1) via the nozzle (7) and the pilot poppet (5) into the spring chamber (8).
The main control spool (1) assumes its control position and keeps the value in the outlet channel set at the spring (6) constant. The pilot oil return from the spring chamber (8) is always realized externally via the Y port (9).
In subplate mounting version "P", a check valve (10) can be optionally installed for free return flow from channel A to B.
Type DR 10 -4-4X/…
Type DR 20 G-4-4X/…
Notice!
The pressure in port Y is added 1:1 to the set reduced pressure.
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
08 |
09 |
10 |
|||
|
DR |
– |
– |
/ |
Y |
* |
|
01 |
Pressure reducing valve |
DR |
|
02 |
Size 10 |
|
|
Subplate mounting "no code" |
10 |
|
|
Threaded connection "G" (G1 1/2) |
10 |
|
|
Size 25 |
||
|
Subplate mounting "no code" |
20 |
|
|
Threaded connection "G" (G3/4) |
15 |
|
|
Threaded connection "G" (G1) |
20 |
|
|
Screw-in cartridge valve "K" |
20 |
|
|
03 |
Subplate mounting |
no code |
|
Threaded connection |
G |
|
|
Cartridge valve |
K |
|
|
Adjustment type |
||
|
04 |
Rotary knob |
4 |
|
Sleeve with hexagon and protective cap |
5 |
|
|
Lockable rotary knob with scale |
6 1) |
|
|
Rotary knob with scale |
7 |
|
|
05 |
Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions); (03 = "K") |
1X |
|
Component series 40 ... 49 (40 ... 49: unchanged installation and connection dimensions); (03 = "no code" and "G") |
4X |
|
|
Pressure rating |
||
|
06 |
Set pressure up to 50 bar |
50 |
|
Set pressure up to 100 bar |
100 |
|
|
Set pressure up to 200 bar |
200 |
|
|
Set pressure up to 315 bar |
315 |
|
|
07 |
Internal pilot oil supply, external pilot oil return |
Y |
|
08 |
With check valve (subplate mounting only) |
no code |
|
Without spring return |
M |
|
|
Seal material |
||
|
09 |
NBR seals |
no code |
|
FKM seals |
V |
|
|
Observe compatibility of seals with hydraulic fluid used. (Other seals upon request) |
||
|
10 |
Further details in the plain text |
* |
| 1) H-key with material no. R900008158 is included in the scope of delivery |
Notice! Preferred types and standard units are specified in the EPS (standard price list).
general
|
Size |
10 | 25 | ||
|
Weight |
Subplate mounting |
kg |
3.2 | 3.5 |
|
Cartridge valve |
kg |
2.5 | 2.8 | |
|
Threaded connection |
kg |
3.6 | 3.3 | |
|
Installation position |
any | |||
|
Ambient temperature range |
NBR seals |
°C |
-30 … +80 | |
|
FKM seals |
°C |
-20 … +80 | ||
hydraulic
|
Size |
10 | 25 | ||
|
Nominal pressure |
bar |
315 | ||
|
Maximum operating pressure |
Inlet |
bar |
315 | |
|
Maximum secondary pressure |
Outlet |
bar |
50 100 200 315 |
|
|
Maximum counter pressure |
Port Y |
bar |
250 | |
|
Set pressure |
Minimum |
flow-dependent, see characteristic curves | ||
|
Maximum |
bar |
50 100 200 315 |
||
|
Maximum flow |
Subplate mounting |
l/min |
80 | 160 |
|
Threaded connection |
l/min |
80 | 160 | |
|
Hydraulic fluid |
see table | |||
|
Hydraulic fluid temperature range |
NBR seals |
°C |
-30 … +80 | |
|
FKM seals |
°C |
-20 … +80 | ||
|
Viscosity range |
mm²/s |
10 … 800 | ||
|
Maximum admissible degree of contamination of the hydraulic fluid 1) |
Class 20/18/15 according to ISO 4406 (c) | |||
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
|
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
|
|
Mineral oils |
HL,HLP |
NBR, FKM |
DIN 51524 |
|
|
Bio-degradable |
Insoluble in water |
HETG |
NBR, FKM |
VDMA 24568 |
|
HEES |
FKM |
|||
|
Soluble in water |
HEPG |
FKM |
VDMA 24568 |
|
|
Containing water |
Water-free |
HFDU, HFDR |
FKM |
ISO 12922 |
|
Containing water |
HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620) |
NBR |
ISO 12922 |
|
|
Important information on hydraulic fluids! For further information and data on the use of other hydraulic fluids, please refer to data sheet 90220 or contact us! There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.)! The flash point of the hydraulic fluid used must be 40 K higher than the maximum surface temperature.Flame-resistant – containing water: The maximum pressure differential per control edge is 210 bar. Otherwise, there is increased cavitation erosion. Maximum hydraulic fluid temperature 60 °C Life cycle as compared to operation with mineral oil HLP 30 to 100 % |
||||
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
Minimum adjustable output pressure P dependent on the flow qV (B to A)
Pilot flow qV st dependent on the flow qV (B to A) and the pressure differential Δp
Δpmin-qV characteristic curve (B to A)
Δp-qV characteristic curve (B to A)
Type DR . .-.-4X/.Y
Subplate mounting
Type DR . .-.-4X/.YM, Type DR . K-.-1X/.YM (screw-in cartridge valve)
Subplate mounting, screw-in cartridge valve
Type DR . G-.-4X/.YM
Threaded connection
Subplate mounting
Dimensions in mm
Subplate mounting
Dimensions in mm
|
1 |
Adjustment type "4" |
|
2 |
Adjustment type "5" |
|
3 |
Adjustment type "6" |
|
4 |
Adjustment type "7" |
|
5 |
Lock nut SW22 |
|
6 |
Hexagon SW10 |
|
7 |
Hexagon SW30, tightening torque for screw-in MA = 50 Nm |
|
8 |
Space required to remove the key |
|
9 |
Locking pin |
|
10 |
Valve mounting bores |
|
11 |
Name plate |
|
12 |
Identical seal rings for ports A and B |
|
13 |
Seal ring for port Y |
|
Type |
L1 |
L2 |
L3 |
L4 |
L5 |
L6 |
B1 |
B2 |
B3 |
B4 |
H1 |
H2 |
H3 |
H4 |
ØD1 |
ØD2 |
ØD3 |
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|
| DR10 | 95.5 | 79 | 42.9 | 23 | 2.5 | 21.5 | 85 | 49 | 66.7 | 7.9 | 71 | 60 | 26 | 26 | 35.5 | 21.8 | 15 |
| DR20 | 96 | 79.5 | 60.3 | 7 | 4 | 39.7 | 100 | 58 | 79.4 | 6.4 | 96 | 78 | 26 | 40 | 41 | 34.8 | 25 |
Threaded connection "G"
Dimensions in mm
|
1 |
Adjustment type "4" |
|
2 |
Adjustment type "5" |
|
3 |
Adjustment type "6" |
|
4 |
Adjustment type "7" |
|
5 |
Lock nut SW22 |
|
6 |
Hexagon SW10 |
|
7 |
Hexagon SW30, tightening torque for screw-in MA = 50 Nm |
|
8 |
Space required to remove the key |
|
10 |
Valve mounting bores |
|
11 |
Name plate |
|
14 |
Y port for pilot oil return |
|
Type |
D1 |
ØD2 |
|
mm |
||
| DR 10G | G1/2 | 34 |
| DR 15G | G3/4 | 42 |
| DR 20G | G1 | 47 |
Notice!
In this valve version, no check valve for free return flow is installed in the valve.
Screw-in cartridge valve "K"
Dimensions in mm
|
1 |
Adjustment type "4" |
|
2 |
Adjustment type "5" |
|
3 |
Adjustment type "6" |
|
4 |
Adjustment type "7" |
|
5 |
Lock nut SW22 |
|
6 |
Hexagon SW10 |
|
7 |
Hexagon SW30, tightening torque for screw-in MA = 50 Nm |
|
8 |
Space required to remove the key |
|
15 |
Seal ring |
|
16 |
Support ring |
Mounting cavity
Dimensions in mm
Notice!
Optionally, the connection bores A, B and Y can be applied at the circumference.
Subplates (separate order)
Size 10:G 460/01 (G3/8)
G 461/01 (G1/2)
Size 25:G 412/01 (G3/4)
G 413/01(G1)
Valve mounting screws (separate order)
Size 10:4 hexagon socket head cap screws ISO 4762 - M10 x 40 - 10.9-flZn-240h-L
(friction coefficient μtotal = 0.09 to 0.14);
Tightening torque MA = 75 Nm ± 10 %
Size 25:4 hexagon socket head cap screws ISO 4762 - M10 x 50 - 10.9-flZn-240h-L
(friction coefficient μtotal = 0.09 to 0.14);
Tightening torque MA = 75 Nm ± 10 %
Notice!
The tightening torques stated are guidelines when using screws with the specified friction coefficients and when using a manual torque wrench (tolerance ± 10 %).