BOSCH REXROTH
R900962622
$2,947.00 USD
- BOSCH REXROTH
- Material:R900962622
- Model:LC63DR40E7X/V
Due to extremely high demand, please call 920-337-0234 for availability
The Bosch Rexroth LC63DR40E7X/V (R900962622) is a high-performance way cartridge valve designed for pressure functions, including pressure reducing applications. This pilot-operated valve comes in both seat and spool designs and is built to fit standardized receiving holes according to DIN ISO, ensuring easy installation and compatibility with various systems. It features a power section that operates as a cartridge valve and is securely sealed with a control cover. The LC63DR40E7X/V boasts an integrated pilot control valve that can be manually or electrically adjusted for proportional pressure, adding to its versatility. The control cover can either house the pilot control valve directly or support an additional pilot valve mounted on top, adhering to mounting dimensions set by DIN standards. This flexibility allows for the realization of different pressure functions when combined with appropriate control covers. For the pressure reducing function, this model operates as a spool valve without an area difference at port B, meaning there are no effective areas at this port. It utilizes cover types similar to those used in the pressure relief function (type LFA..DB...), ensuring reliable performance. The pressure at port A is regulated through the pilot oil supply orifice leading to the spring side of the spool. Under normal conditions and within set pressures, the spool remains balanced by spring force allowing free flow from port B to A. Once the system reaches the pre-set pressure limit, the spool closes, effectively reducing the pressure at port A according to its specific pressure-flow characteristics. The LC63DR40E7X/V is designed to handle maximum flow rates efficiently while maintaining stable operation under various conditions, making it an essential component for hydraulic systems requiring precise pressure management.
General
2-way cartridge valves for pressure functions are pilot-operated valves in seat or spool design. The power section designed as cartridge valve (1) is installed into a receiving hole standardized according to DIN ISO 7368 and closed with a control cover (2).
The pilot control valve (4) for manual or electrically proportional pressure adjustment is integrated into the control cover (2) or is installed on the control cover (2) as pilot valve with mounting dimensions according to DIN 24 340.
By combination of cartridge valves with the control covers, different pressure functions can be realized. .
Pressure reducing function
Rest position open
The cartridge valve for the pressure reducing function is designed as spool valve without area difference (no effective areas at port B).
As pilot control valve, identical cover types as for the pressure relief function are applied (type LFA..DB...).
The effective pressure at port A is directed via the pilot oil supply orifice to the spring side of the spool. Under the performance limit and the pressure set at the pilot control valve, the spool is pressure-compensated and retained in open position by the spring force to enable free flow from port B to port A.
On reaching the set pressure, the spool is closed and the pressure at port A is reduced according to the pressure-flow characteristics.
|
Type |
||
|
01 |
Cartridge valve |
LC |
|
Size |
||
|
02 |
NG 16 |
16 |
|
NG 25 |
25 |
|
|
NG 32 |
32 |
|
|
NG 40 |
40 |
|
|
NG 50 |
50 |
|
|
NG 63 |
63 |
|
|
Version |
||
|
03 |
Pressure relief function |
DR |
|
Cracking pressure |
||
|
04 |
Cracking pressure 0 bar (without spring) |
00 |
|
Cracking pressure approx. 2 bar |
20 |
|
|
Cracking pressure approx. 3 bar 1) |
30 |
|
|
Cracking pressure approx. 4 bar |
40 |
|
|
Cracking pressure approx. 5 bar (NG16, 25 and 32 only) |
50 |
|
|
Cracking pressure approx. 8 bar 2) |
80 |
|
|
Damping |
||
|
05 |
Piston without precision grooves |
E |
|
Component series |
||
|
06 |
Component series 70 ... 79 (70 ... 79: unchanged installation and connection dimensions) |
7X |
|
Seal material |
||
|
07 |
NBR seals |
no code |
|
FKM seals |
V |
|
|
01 |
02 |
03 |
04 |
05 |
06 |
07 |
|
|
LC |
DR |
E |
7X |
/ |
Additional preferred types and standard units are specified in the EPS (standard price list).
|
Hydraulic fluid |
Classification |
Suitable sealing materials |
Standards |
|
|
Mineral oil |
HL, HLP |
FKM, NBR |
DIN 51524 |
|
|
Bio-degradable |
Insoluble in water |
HEES (synthetic esters) |
FKM |
VDMA 24568 |
|
HETG (rape seed oil) |
FKM, NBR |
|||
|
Soluble in water |
HEPG (polyglycols) |
FKM |
VDMA 24568 |
|
|
Other hydraulic fluids on request |
||||
hydraulic
|
Size |
16 | 25 | 32 | 40 | 50 | 63 | ||
|
Maximum operating pressure |
Port A |
bar |
315 | |||||
|
Port B |
bar |
315 | ||||||
|
Maximum flow |
LC..DR20.../.. |
l/min |
100 | 200 | 300 | 750 | 1000 | 1600 |
|
LC..DR40.../.. |
l/min |
150 | 300 | 450 | 1000 | 1300 | 2000 | |
|
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524; fast biodegradable hydraulic fluids according to VDMA 24568 ; HETG (rape seed oil); HEPG (polyglycols); HEES (synthetic esters), other hydraulic fluids on request | |||||||
|
Hydraulic fluid temperature range |
NBR seals |
°C |
-30 … +80 | |||||
|
FKM seals |
°C |
-20 … +80 | ||||||
|
Viscosity range |
mm²/s |
2.8 … 380 | ||||||
|
Maximum admissible degree of contamination of the hydraulic fluid 1) |
Class 20/18/15 according to ISO 4406 (c) | |||||||
| 1) | The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter. |
For applications outside these parameters, please consult us!
(measured with HLP46, ϑOil = 40 ±5 °C)
LC 16 DR…
LC 16 DR…
LC 16 DR…
LC 16 DR…
(measured with HLP46, ϑOil = 40 ±5 °C)
LC 25 DR…
LC 25 DR…
LC 25 DR…
LC 25 DR…
(measured with HLP46, ϑOil = 40 ±5 °C)
LC 32 DR…
LC 32 DR…
LC 32 DR…
LC 32 DR…
(measured with HLP46, ϑOil = 40 ±5 °C)
LC 40 DR…
LC 40 DR…
LC 40 DR…
LC 40 DR…
(measured with HLP46, ϑOil = 40 ±5 °C)
LC 50 DR…
LC 50 DR…
LC 50 DR…
LC 50 DR…
(measured with HLP46, ϑOil = 40 ±5 °C)
LC 63 DR…
LC 63 DR…
LC 63 DR…
LC 63 DR…
|
Version "E" |
Version “D” |
||
|
Area ratio |
Area ratio |
Area ratio |
Area ratio |
Installation bore and connection dimensions according to ISO 7368
Dimensions in mm
|
1 |
Depth of fit |
|
2 |
Control dimension |
|
3 |
If a different diameter is used for port B than ØD3 or (ØD3*), the distance from the cover support surface to the bore center must be calculated. |
|
4 |
Port B may be positioned around the central axis of port A. However, it must be observed that the mounting bores and the control bores are not damaged. |
|
7 |
At Ø ≤45 mm → Fitting H8 admissible |
|
NG |
ØD1 |
ØD2 |
ØD3/(ØD3*) |
ØD4 |
ØD5 |
ØD6 1) |
ØD7 |
H1/(H1*) |
H2 |
H3 |
H4 |
H5 |
H6 |
H7 |
H8 |
H9 |
L1 |
L2 |
L3 |
L4 |
L5 |
W |
|||
|
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
|||||
| 16 | 32 |
H7 - |
16 |
16 25 |
25 |
H7 - |
M8 | 8 | 4 |
H13 - |
35 29.5 |
56 | 43 | 20 | 11 | 2 | 20 | 2 | 0.5 |
65 80 |
46 | 23 | 25 | 10.5 | 0.05 |
| 25 | 45 |
H7 - |
25 |
25 32 |
34 |
H7 - |
M12 | 6 | 6 |
H13 - |
44 40.5 |
72 | 58 | 25 | 12 | 2.5 | 30 | 2.5 | 1 |
85 - |
58 | 29 | 33 | 16 | 0.05 |
| 32 | 60 |
H7 - |
32 |
32 40 |
45 |
H7 - |
M16 | 8 | 6 |
H13 - |
52 48 |
85 | 70 | 35 | 13 | 2.5 | 30 | 2.5 | 1.5 |
102 - |
70 | 35 | 41 | 17 | 0.1 |
| 40 | 75 |
H7 - |
40 |
40 50 |
55 |
H7 - |
M20 | 10 | 6 |
H13 - |
64 59 |
105 | 87 | 45 | 15 | 3 | 30 | 3 | 2.5 |
125 - |
85 | 42.5 | 50 | 23 | 0.1 |
| 50 | 90 |
H7 - |
50 |
50 63 |
68 |
H7 - |
M20 | 10 | 8 |
H13 - |
72 65.5 |
122 | 100 | 45 | 17 | 3 | 35 | 4 | 2.5 |
140 - |
100 | 50 | 58 | 30 | 0.1 |
| 63 | 120 |
H7 - |
63 |
63 80 |
90 |
H7 - |
M30 | 12 | 8 |
H13 - |
95 86.5 |
155 | 130 | 65 | 20 | 4 | 40 | 4 | 3 |
180 - |
125 | 62.5 | 75 | 38 | 0.2 |
| 1) | Maximum dimension |