You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
R901247785


$671.00 USD
  • BOSCH REXROTH
  • Material:R901247785
  • Model:ABZMT-1X/0300MS/D0-T4-K24

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Bosch Rexroth directly.***
The Bosch Rexroth ABZMT-1X/0300MS/D0-T4-K24 (R901247785) is an advanced electronic contact thermometer with a measuring transducer designed for precise temperature control of hydraulic systems. This device features a directly attached display that allows users to select temperature readings in either Celsius or Fahrenheit. The menu navigation adheres to the VDMA standard sheet for fluid sensors, ensuring user-friendly operation. This model boasts a microprocessor-controlled display and control unit that processes analog input signals for accurate temperature analysis. Operators can easily set temperatures using pushbuttons, and the LED display provides clear readings. The unit includes up to four seven-segment LED displays and integrated LEDs on the front plate to indicate alarm conditions. The ABZMT-1X/0300MS/D0-T4-K24 offers flexible output options, including two to four PNP switching outputs, which are freely adjustable, as well as one programmable output that can be set as a frequency output. Alternatively, it provides one programmable PNP switching output alongside an analog output that ranges from 4...20 mA for continuous temperature measurement. Parameterization is intuitive with a hierarchical tree structure menu that simplifies access to commonly used functions while providing submenus for less frequent adjustments. The device ensures all settings are retained even during power loss, with max/min values retrievable from permanent memory when needed. Suitable for use with hydraulic fluids such as HLP, HFDU, and HETG, this model conforms to CE standards for electromagnetic compatibility within the EU and comes with an electrical connector described as Connector pole, Mx A-coded. It operates on a supply voltage range of 8...32 V DC and has a weight specification provided by the manufacturer. Its compact radial design makes it ideal for integration into highly compact systems without sacrificing performance or accessibility.


Temperature sensor and measuring transducer

Temperature sensor and transducer

Unpacked Weight: 0.20941 kg

Electronic contact thermometers are used for the temperature control of hydraulic systems.

The contact thermometers have two or four programmable temperature switching outputs, or alternatively one programmable switching output and one analog output 4 … 20 mA, with display and control unit.

The temperature display can be selected in °C or °F.

Display and control unit function

The micro-processor controlled display and control unit processes the analog input signals for the analysis of the temperature control. The temperature can be set at the control unit in an easy menu navigation by means of pushbuttons and the settings can be read off at the LED display.

 

The display and control unit has a four-digit, red seven-segment LED display and 3 pushbuttons for the operation as well as up to 4 LEDs integrated in the front plate for the display of alarm conditions.

The device moreover has two (t2) and/or four (T4) freely adjustable PNP switching outputs plus the adjustable switch-back points. One PNP output can be programmed as frequency output. Alternatively one freely programmable PNP switching output and one 4 ... 20 mA output for the continuous temperature measurement. The switching conditions are shown in the display which can be rotated by 270° (version D0).

 

The output 4 … 20 mA can optionally be set to 0 … 10 V, 2 … 10 V or 0 … 5V.

Depending on the setting for the measured temperature, the desired unit (°C, °F) will be displayed. By default, the temperature display is set to °C.

During the setting and/or programming of the corresponding process parameters, the parameter values and/or the related menu items are shown in the display. In case of energy supply failure, all input values will be stored, the max/min values can be called from a permanent memory, if necessary.

 

Parameterization

The menu navigation is based on the VDMA standard sheet for fluid sensors 24574-1.

The operating menu is designed hierarchically as tree structure.

That means that frequently used functions and adjustment points are quickly accessible and rarely used menu items can be found in a submenu.

Using the ▲ and ▼ keys, the corresponding parameters are set and/or the next menu item is displayed.

Using the ► key, the selected menu item is selected and/or the set parameter is accepted and stored.

The parameter may be a numerical value and a selection of functions (e.g. NO [output as normally open contact], NC [output as normally closed contact] or i1 [analog output 4 … 20 mA]).

After confirmation of a parameter or function selection by means of the ► key, the display will switch back to the current menu item. Then, you can use ▲ and ▼ to display the next menu item and the ► key to select it.

Electronic contact thermometers are used for the temperature control of hydraulic systems
Directly attached display
°C or °F can be selected
The menu navigation is based on the VDMA standard sheet for fluid sensors 24574-
Radial compact sets for highly compact designs
Max. pressure5
Electrical connection description2 x connector 4-pole, M12 x 1, coding A according to EN 61076-2-101
Productgroup ID9,10,11,12,13,14
Conformity descriptionCE – electromagnetic compatibility 2014/30/EU
Length300
Displayyes
Connection diagramMale thread G1/2
Supply voltage10..32 VDC
Weight0.20941
Output signal4 switching outputs
Hydraulic fluidHLP,HFDU,HETG
ConformityCE

Ordering code

01

02

03

04

05

06

07

08

ABZM

T

1X

/

/

K24

Power unit accessories

01

Measuring devices

ABZM

02

Electronic contact thermometer

T

03

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

Sensor length in mm

04

L = 200 mm

0200

L = 300 mm

0300

L = 500 mm

0500

L = 1000 mm

1000

Sensor

05

Brass MS (with NBR seal)

MS

Stainless steel 1.4571 (with FKM seal)

ES

Display and control unit

06

Directly attached display and control unit

D0

External display and control unit with cable set M12 x 1; 4-pole, PUR

1500 mm, mating connector angled and line connector straight

E1

3000 mm, mating connector angled and line connector straight

E3

5000 mm, mating connector angled and line connector straight

E5

Temperature

07

Temperature display and two programmable switching outputs

T2

Temperature display and four programmable switching outputs

T4

Temperature display, one programmable switching output and one analog output 4 … 20 mA

T1A

Electrical connection 1)

08

Connector, 4-pole M12 x 1

K24

1) The mating connectors are not included in the scope of delivery and must be ordered separately, if required (see R.08006).
Order example:
Electronic contact thermometer, sensor length 300 mm, sensor in brass, directly attached control and indicator unit, temperature display and two programmable switching outputs, connector K24:
ABZMT-1X/0300MS/D0-T2-K24

electrical

Plug-in connection

4-pole M12 x 1 (material: metal)

Temperature sensor Pt100

Sensor element

Pt100 class B DIN EN 60751

Temperature measuring range

°C

0 … 100

Accuracy

K

± 0.8

Display and control unit

Power supply

V DC

10 … 32

Maximal contact load

A

1

Display range

°C

-20 … +120

Alarm adjustment range

°C

​0 … ​100

Housing design

PA, IP65 (antistatisch)

Current consumption upon switch-on

more than 100 ms

mA

≈ 100

Current consumption during operation

with UB 24 V

mA

≈50

Operation

3 keys

Version T2

Switching points

2 programmable switching outputs

Maximum switching current

per output

A

0.5

Total

A

1

Version T4

Switching points

4 programmable switching outputs

Maximum switching current

per output

A

0.5

Total

A

1

Version T1A

Switching points

1 programmable switching output

Maximum switching current

per output

A

0.5

Total

A

1

Output signal 1)

mA

4 … 20

Maximum load

Ω

500

Mounting of external display and control unit

Assembly on top hat rail 35 mm
1) Alternatively 0 … 10, 2 … 10 or 0 … 5 V adjustable

Resistance

Hydraulic fluids

Seals

NBR

FKM

Mineral oils

Mineral oil

HL/HLP

according to DIN 51524

Resistant

Resistant

Flame-resistant hydraulic fluids

Emulsions

HFA-E

according to DIN 24320

Not resistant

Water solutions

HFC

according to VDMA 24317

Not resistant

Phosphoric acid esters

HFD-R

Organic esters

HFD-U

Resistant

Fast bio-degradable hydraulic fluids

Triglycerides (rape seed oil)

HETG

according to VDMA 24568

Synthetic esters

HEES

Not resistant

Polyglycols

HEPG

For applications outside these parameters, please consult us!

Two programmable switching outputs for temperature (T2)

technical illustration-r901247785-Temperature sensor and measuring transducer

Four programmable switching outputs for temperature (T4)

technical illustration-r901247785-Temperature sensor and measuring transducer

One programmable switching output and one analog output 4 … 20 mA for temperature (T1A)

technical illustration-r901247785-Temperature sensor and measuring transducer

Pinout

Switching function plug-in connection M12 x 1

Version

T2

technical illustration-r901247785-Temperature sensor and measuring transducer technical illustration-r901247785-Temperature sensor and measuring transducer
1) 0 ... 100 °C freely programmable

Connector B not available

T4

technical illustration-r901247785-Temperature sensor and measuring transducer technical illustration-r901247785-Temperature sensor and measuring transducer technical illustration-r901247785-Temperature sensor and measuring transducer

T1A

technical illustration-r901247785-Temperature sensor and measuring transducer technical illustration-r901247785-Temperature sensor and measuring transducer
1) 0 ... 100 °C freely programmable

Connector B not available

Dimensions: Directly attached display and control unit

(version D)

Dimensions in mm

technical illustration-r901247785-Temperature sensor and measuring transducer

1

Immersion depth at least 30 mm

2

Profile seal G1/2

3

Name plate

4

Mating connector for plug-in connections K24 (M12 x 1), see table "Mating connector"

5

Connector K24; 4-pole M12 x 1

6

LEDs for the display of alarm switching points

7

Connector B only with version T4

8

Display and control unit can be rotated by 270°

Dimensions: External display and control unit

(version E)

Dimensions in mm

technical illustration-r901247785-Temperature sensor and measuring transducer

1

Immersion depth at least 30 mm

2

Profile seal G1/2

3

Name plate

4

Mating connector for plug-in connections K24 (M12 x 1), see table "Mating connector"

5

Connector K24; 4-pole M12 x 1

6

LEDs for the display of alarm switching points

7

Connector B only with version T4

8

Display and control unit

9

Cable set M12 x 1; 4-pole, PUR, see "Ordering code"

Assembly external display and control unit

technical illustration-r901247785-Temperature sensor and measuring transducer

1

Top hat rail TS35 DIN EN 60715 (R900016056)

1.1

Hexagon socket head cap screw M5

2

Clamping bracket E/NS35N (R900227399)

3

External display and control unit

3.1

Mounting clip

Installation information

Shorten the top hat rail item 1 (supplied length 2000 mm) to the required dimension and fasten it on the substructure using hexagon socket head cap screws M5 item 1.1 Position the display and control unit item 3 on the top hat rail and fast it using the fastening clip item 3.1 Fix the display and control unit item 3 by means of the clamping bracket item 2 on both sides

The fastening accessories item 1, item 1.1 and item 2 are not included in the scope of delivery of item 3.

 

Avoid flows Do not expose the switch to heavy impacts and bends Avoid external magnetic fields

 

Electrical connections:

Electrical connections may only be established by specialists Tighten the round connectors M12 x 1 and/or mating connectors after connection Only plug in the round connectors M12 x 1 and/or mating connectors in the de-energized condition Tightening torque of the screw-in stud 25 Nm In case of inductive load provide a protection circuit!

Normative references

R 08006

Mating connectors for controlling electrically operated valves and sensors

 

DIN 24320

Flame-resistant fluids – Hydraulic fluids of categories HFAE and HFAS – Properties and requirements

 

DIN 51524

Hydraulic fluids; hydraulic oils

 

DIN EN 60715

Dimensions of low-voltage switchgear and control gear – Standardized mounting on rails

 

DIN EN 60751

Industrial platinum resistance thermometers and platinum temperature sensors (IEC 60751:2008)

 

DIN EN 175201-804:

Detail specification – Circular connectors – Round contacts, size diameter 1.6 mm; threaded coupling; German version EN 175201-804:1999

 

DIN EN 175301-803:

Detail specification: Rectangular connectors – Flat contacts, 0.8 mm thickness, locking screw not detachable; German version EN 175301-803:1999

 

DIN EN 60529

Degrees of protection provided by enclosures

 

VDMA 24317

Fluid technology – Flame-resistant fluids – Technical minimum requirements

 

VDMA 24568

Fluid technology – Fast biodegradable hydraulic fluids – Technical minimum requirements

 

VDMA 24574-1

Fluid technology – Terms, menu navigation and electrical connection for fluid sensors

Accessories: (not included in scope of delivery)

Tank installation sleeveMaterial no. R901248320 technical illustration-r901247785-Temperature sensor and measuring transducer

Mating connectors

For detailed information see data sheet 08006

Mating connector for connector K24

Mating connector for connector K24 with potted-in PVC cable, 3 m long

Denomination

Part number

Denomination

Part number

LEITUNGSDOSE 4P Z24 SPEZ

R900031155

LEITUNGSDOSE 4P Z24M12X1+3MSPEZ

R900064381

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1

4P Z24

technical illustration-r901247785-Temperature sensor and measuring transducer

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1

4P Z24

For sensors and valves with connector “K24”, “K35” and “K72” Mating connectors M12, 4-pole, line cross-section 0.75 mm2

Data sheet

Spare parts & repair

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line

4P Z24 +

technical illustration-r901247785-Temperature sensor and measuring transducer

Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line

4P Z24 +

For sensors and valves with connector “K24”, “K35” and “K72” Mating connectors M12, 4-pole, line cross-section 0.75 mm2

Data sheet

Spare parts & repair

Use in explosive areas according to directive 94/9/EC (ATEX)

The electronic contact thermometers according to ABZMT are not suitable for the use in explosive areas.