CALL US
920.337.0234
FSC Acquires Norcan

BOSCH
0811405041

$1,141.00

BOSCH

MATERIAL:  0811405041

Due to extremely high demand, please call 920-337-0234 for availability

01

Valve amplifiers for proportional valves without electrical position feedback, Analog, Connector design

VT-SSPA1

02

For valves: universal, 2.5 A/25 W

525

03

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

04

Version: standard

V0

01

02

03

04

VT-SSPA1

525

1X

/

V0

General

Component series

1X

Material number

Data sheet

1819929030

Type of electronics

Analog

Design

Plug-in connector

Voltage supply

Operating voltage

nominal

UB

V

12/24

Lower limit value

UB(t)min

V

11

Upper limit value

UB(t)max

V

36

Ripple

%

< 10

Power consumption

max.

Smax

VA

30

Fuse

3 A

Analog inputs

Command value source

Potentiometer 1...10 kΩ supplied with internal reference voltage 8 V

Command value 1)

grounded on one side, first input

Ucommand

V

​0 … ​8
1) <0,3 V, solenoid de-energized

Solenoid outputs

Solenoid current

max.

Imax

A

2.5

Solenoid output

other properties

Clocked, pulse-modulated, short-circuit-proof

Cable length

for 1.5 mm2

m

20

for 2.5 mm2

m

40

Adjustment options

Zero point calibration information

See characteristic curves

Range sensitivity adjustment

See characteristic curves

Supplementary information

Reference voltage

Potentiometer supply

U

V

8 (Imax = 10 mA)

Special features

Outputs short-circuit-proof, fast energization for short actuating time

Standard connection

of solenoid

DIN 43650

Connection cross-section

A

4 x 1,5 mm2 / 2,5 mm2

Anschlussart

Plug-in connector

Type of protection according to EN 60529 1)

Extra für FN

IP65

Ambient temperature range

ϑ

°C

-20 … ​70

Storage temperature range

ϑ

°C

-20 … ​85

Weight

m

kg

0.203
1) Including socket

For applications outside these parameters, please consult us!

technical illustration-0811405041-Differential input Adjustable zero point and sensitivity 24&nbsp;V operating voltage Connection via 4-pole connector
technical illustration-0811405041-Differential input Adjustable zero point and sensitivity 24&nbsp;V operating voltage Connection via 4-pole connector
technical illustration-0811405041-Differential input Adjustable zero point and sensitivity 24&nbsp;V operating voltage Connection via 4-pole connector

Dimensions in mm

technical illustration-0811405041-Differential input Adjustable zero point and sensitivity 24&nbsp;V operating voltage Connection via 4-pole connector

Dimensions in mm

technical illustration-0811405041-Differential input Adjustable zero point and sensitivity 24&nbsp;V operating voltage Connection via 4-pole connector

The plug-in proportional amplifier may only be wired in de-energized condition.

Do not lay lines close to power cables.

The distance to aerial lines, radios, and radar systems has to be at least 1 m.

To set the potentiometers and to check the current values, use the measuring adapter and measure the currents in a potential-free manner.

The specified maximum solenoid currents must not be exceeded.

Do not use solenoids with integrated free-wheeling diodes.

The supply voltage is to be protected by means of a fuse – see “Technical data”.