01

Valve amplifier for high-response valves with one solenoid, analog, euro-card format

VT-VRRA1

02

For valves:
4WRL 10 … 35 V/V1…P-3X…
4WRL 10 … 25 V/V1…P-3X…-750

527

03

Component series 20 ... 29 (20 ... 29: unchanged technical data and pin assignment)

2X

04

Version: standard

V0

05

For pilot-operated high-response valve, progressive with linear fine control

2STV

01

02

03

04

05

VT-VRRA1

527

2X

/

V0

/

2STV

General

Component series

2X

Type of electronics

Analog

Design

Euro-card

Voltage supply

Operating voltage

nominal

U

V

24

Lower limit value

UB(t)min

V

21

Upper limit value

UB(t)max

V

40

Ripple 1)

%

< 10

Power consumption

P

VA

37

Current consumption

max.

Imax

A

1.7
1) In case of ripple > 10 %, an upstream smoothing capacitor is required (recommendation: capacitor module VT 11110)

Analog inputs

Command value source

Potentiometer 10 kΩ supplied with 10 V internal reference voltage, external signal source

Command value

Voltage

Differential input

U

V

​0 ... ±10

Input resistance

R

≥ 100

position value

Voltage

U

V

±10

Digital inputs

Enable 1)

On (active)

U

V

8.5 ... 40
1) RE = 100 kΩ

Digital outputs

Cable break error message

No error 1)

UB

V

24

Error

UB

V

0
1) Imax = 100 mA

Solenoid outputs

Solenoid current

max.

Imax

A

2.7

Solenoid output

other properties

Clocked current controller

Cable length

for 1.5 mm2

L

m

20

for 2.5 mm2

L

m

60

Position transducer

Line cross-section

Position transducer line

A

4 x 0.5 mm2 (shielded)

Position transducer supply

U

V

±15

Adjustment options

Zero point calibration setting range

%

± 5

Displays

LED display

Green 1

Enable

Yellow 1

Cable break actual value

Red

UB too low

Other information

Reference voltage

Potentiometer supply

U

V

±10 (Imax = 10 mA)

Special features

Short-circuit-proof outputs, cable break detection for actual value line, position control with PID behavior, fast energization and fast deletion for short actuating times

Anschlussart

32-pin male connector, DIN 41612, form F

Ambient temperature range

ϑ

°C

​0 … ​70

Storage temperature range

ϑ

°C

-20 … ​70

Weight

m

kg

0.36

For applications outside these parameters, please consult us!

technical illustration-0811405063-Controlled output stage Closed-loop position control with PID characteristics Fast energization and fast deletion for short actuating times Enable input Short-circuit-proof outputs Adjustable zero point Cable break detection for actual value cable
technical illustration-0811405063-Controlled output stage Closed-loop position control with PID characteristics Fast energization and fast deletion for short actuating times Enable input Short-circuit-proof outputs Adjustable zero point Cable break detection for actual value cable

Dimensions in mm

technical illustration-0811405063-Controlled output stage Closed-loop position control with PID characteristics Fast energization and fast deletion for short actuating times Enable input Short-circuit-proof outputs Adjustable zero point Cable break detection for actual value cable

Dimensions in mm

technical illustration-0811405063-Controlled output stage Closed-loop position control with PID characteristics Fast energization and fast deletion for short actuating times Enable input Short-circuit-proof outputs Adjustable zero point Cable break detection for actual value cable

The amplifier card may only be unplugged and plugged when de-energized.

The distance to aerial lines, radios, and radar systems has to be at least 1 m.

Do not lay solenoid and signal lines near power cables.

For signal lines and solenoid conductors, we recommend using shielded cables.
The cable shield must be connected to the control cabinet extensively and as short as possible.

The valve solenoid must not be connected to free-wheeling diodes or other protection circuits.

The cable lengths and cross-sections specified in the technical data must be complied with.

Wiring information

Power zero b2 and control zero b12 or b14 or z28 must be separately led to the central ground (neutral point).