CALL US
920.337.0234
FSC Acquires Norcan

BOSCH
0811405147

$3,760.00

BOSCH

MATERIAL:  0811405147

Due to extremely high demand, please call 920-337-0234 for availability

Force control

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Qcommand

Direction

pdiff. command

Direction

Track traveling

Force control

+5,0​ V

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

+3,5​ V

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

with 50 % vmax.

after track traveling to 35 % of pdiff. max.

+7,5​ V

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

-2,0​ V

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

with 75 % vmax.

not possible

-3,3​ V

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

-4,8​ V

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

with 33 % vmax.

after track traveling to 48 % of pdiff. max.

-10,0​ V

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

+8,0​ V

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

with vmax.

not possible

A command value of at least ±0.3 V must be specified!

The numerical values listed in the table are examples, the signs of the values are decisive.

01

02

03

04

05

06

07

08

09

VT

V

A

C

A

F

500

10

/

V0

01

VT

02

V

Hydraulic component (control)

03

Axis control

A

Valve type

04

High-response valve

C

Control

05

Analog

A

Function

06

Δp/Q control

F

Serial number for types

07

Standard variant without valve amplifier function

500

08

Component series 10 ... 19 (10 ... 19: unchanged technical data and pin assignment)

1X

Customer version

09

Catalog version

V0

General

Supply voltage
UB at z2 ‒ b2

nominal 24 V=
battery voltage 21...40 V,
rectified alternating voltage Ueff = 21...28 V
(single-phase, full-wave rectifier)

Smoothing capacitor, separately
at z2 – b2

Recommendation: Capacitor module VT 11110 (see data sheet 30750)
(only necessary if the ripple of UB >10 %)

Current consumption, max.

mA

250

Command value Q

b20: 0...±10 V – differential amplifier
z20: 0...±10 V – differential amplifier
(Ri= 100 kΩ)

Command value pdiff

z10: 0...+10 V – differential amplifier
z12: 0 V – differential amplifier

Actual value from the pressure sensor

A

b26: 0...±10 V – differential amplifier
b28: 0 V – differential amplifier
z24:
z30: 4...20 mA

B

b16: 0...±10 V – differential amplifier
b18: 0 V – differential amplifier
z14:
z30: 4...20 mA

Pressure sensor supply

z6: +15 V, max. 100 mA
z8: -15 V, max. 100 mA

Pressure controller OFF

b10: 6...40 V=

External controller enquiry

V=

z24: 24 V/0.1 A max., if controller is not active

Signal source

Supply ±10 V from b32, z32 (10 mA) or external signal source

Monitor signal Factual

z16: ±10 V

Error pressure sensor
(cable break, signal lines)

b22: no error: +UB; max. 100 mA
error: 0 V
: LED "Ramp OFF A" and
"Ramp OFF B" flash

Ramp times

min. 350 ms (1), max. 5.6 s (16)
16 stages, 350 ms/stage

Ramp OFF

A

z22: 8...40 V =

B

z26: 8...40 V =

Area adjustment cylinder

min. 1:1 (1), max. 1:4 (16)
16 stages

LED displays

red

Error UB

red

Ramp OFF A

red

Ramp OFF B

green

Controller active

yellow

Controller not active

off

Controller OFF

Plug-in connection

Plug to DIN 41612-F32

Operating temperature

°C

​0 … +70

Storage temperature range

°C

-20 … +70

Weight

m

kg

0.44

Power zero b2 and control zero b12 or b14 or z28 must be separately led to the central ground (neutral point).

For applications outside these parameters, please consult us!

a

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Ideal development

(only a square is shown)

b

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Problem:

P share too small

Solution:

➝ Rotate Kp against 16 (fine adjustment)

→ P gain > see table 2, DIL 11–13

c

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Problem:

P share too large

Solution:

→ Rotate Kp against 1 (fine adjustment)

→ Use DIL 11–13 to reduce the P gain according to table 2

d

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Problem:

P share correct, control deviation too large

Solution:

→ Increase the I gain share according to table 3

→ Rotate KI against 16

e

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Problem:

Time constant of the I share too low

Solution:

➝ Rotate KI against 16 until control deviation and vibration are perfect

→ if KI = 16 is not sufficient, the P share must also be reduced, see table 2

f

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Problem:

D share too low

Solution:

➝ Rotate KD against 16

→ D share >, see table 1 (DIL 6–10)

Front plate

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Block diagram with pin assignment

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Wiring diagram with valve amplifier card

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Wiring diagram – Valve with installed electronics

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor
technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Dimensions in mm

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Example 1

Welding machine

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor

Example 2

Vehicle twisting test stand

technical illustration-0811405147-Suitable for controlling high-response valves Amplifier with additional electronics (daughter card) Analog amplifiers in Europe format for installation in 19" racks Pressure differential controller (force controller) with PID behavior Short-circuit-proof outputs External shut-off for pressure controller External shut-off for pressure controller Separate acceleration and braking ramp Ramps can be separately adjusted and switched off Adjustable area adjustment for cylinder Suitable for pressure sensors (0...10 V, 4...20 mA), see data sheet 30271 Supply for pressure sensors Cable break detection for pressure sensor