BOSCH REXROTH
R901363048
$153.00 USD
- BOSCH REXROTH
- Material:R901363048
- Model:VT-SSBA1-PWM-1X/V001/10
Due to extremely high demand, please call 920-337-0234 for availability
The Bosch Rexroth VT-SSBA1-PWM-1X/V001/10 (R901363048) is a state-of-the-art switching amplifier designed for direct mounting on the K connector of a valve. This device is engineered to operate with a direct voltage supply and features an enable input that, when activated with a high signal, applies a specific voltage profile to the valve as per the functional diagram. When this enable input is switched, it triggers a flashing yellow LED status display as an indicator. This fast switching amplifier significantly improves the response time of standard directional valves equipped with 24V solenoids by initially overexciting the solenoid with 24V for a brief period before reducing the voltage and setting the necessary holding current through pulse width modulation (PWM). The technical data section provides detailed switching time tables that show how various valves correspond with this particular switching amplifier. In addition to enhancing switching speeds, the VT-SSBA1-PWM-1X/V001/10 also offers energy-saving benefits. For systems utilizing 24V standard directional valves, this amplifier markedly lowers continuous current to conserve energy. After a certain duration of power supply and subsequent hydraulic actuation of the valve, it transitions to PWM, substantially diminishing power consumption and ensuring that holding power remains below what would be required by a 24V valve at 24V supply voltage. Energy saving tables in the technical data further delineate which valves are compatible with this feature. Moreover, this device offers PWM at 24V with an on/off ratio that is detailed within its order specifications. The Bosch Rexroth VT-SSBA1-PWM-1X/V001/10 presents an advanced solution for optimizing valve performance while simultaneously cutting down on energy usage in various applications requiring precise control of hydraulic systems.
The switching amplifier VT-SSBA1-PWM is directly mounted at the K4 connector of the valve.
It is supplied with 24 V direct voltage. If at wire 2 (enable "IN"), a high-signal is applied, the voltage profile is applied at the valve according to the functional diagram. If the enable input is switched, the status display LED is flashing "yellow".
Fast switching (V001)
As fast switching amplifier, the VT-SSBA1-PWM considerably reduces the switching time of standard directional valves in connection with 12 V solenoids.
On switching on, the solenoid is overexcited with 24 V by 100 %. Afterwards, the voltage is reduced and the required holding current is set via pulse width modulation.
The switching time table in section Technical data illustrates the assignment of the valves to the switching amplifier.
Energy saving (V002)
If 24 V standard directional valves are used, the switching amplifier considerably reduces the continuous current to save energy.
After a defined power supply time and the connected hydraulic switching of the valve, the system switches to pulse width modulation and the power is considerably reduced. This leads to a holding power under the power of a 24 V valve at 24 V supply voltage.
The table on energy saving in section Technical data illustrates the assignment of the valves to the switching amplifier.
PWM at V002: on/off ratio = 60/40
|
01 |
Connector switching amplifier with pulse width modulation (PWM) |
VT-SSBA1-PWM |
|
02 |
Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions) |
1X |
|
03 |
Quick switching of valves with 12 V solenoids |
V001 |
|
Energy saving by power reduction at valves with 24 V solenoids |
V002 |
|
|
04 |
Cable length 5 m |
5 |
|
Cable length 10 m |
10 |
|
|
Cable length 15 m |
15 |
|
|
05 |
Further details in the plain text |
* |
|
01 |
02 |
03 |
04 |
05 |
|||
|
VT-SSBA1-PWM |
‒ |
1X |
/ |
/ |
* |
General
|
Type / version |
VT-SSBA1-PWM-1X/V001 | VT-SSBA1-PWM-1X/V002 | |
|
Component series |
1X | ||
|
Design |
Plug-in connector | ||
Electric
|
Type / version |
VT-SSBA1-PWM-1X/V001 | VT-SSBA1-PWM-1X/V002 | |||
|
Operating voltage |
nominal |
U |
V |
24 | |
|
Lower limit value |
UB(t)min |
V |
21.6 | ||
|
Upper limit value |
UB(t)max |
V |
26.4 | ||
|
Control voltage |
ON |
U |
V |
10…30 (I = 2.5…12 mA) | |
|
OFF |
U |
V |
<3.5 | ||
|
Clock frequency PWM switching amplifier |
f |
PWM operation 300…500 Hz | |||
|
Switch-on pulse duration |
t |
ms |
100…115 | 300…330 | |
|
PWM duty factor |
t |
% |
40 ±5 on | 60 ±5 on | |
|
Holding current |
Imax |
A |
2 | ||
Sonstige Angaben
|
Type / version |
VT-SSBA1-PWM-1X/V001 | VT-SSBA1-PWM-1X/V002 | |||
|
Connection to the solenoid |
Standard |
EN 175301-803 | |||
|
Connection cross-section |
S |
4 x 0.75 mm2 | |||
|
Anschlussart |
Potted-in cable with open end, jacket: PUR-JZ black, wire insulation: PP black, green/yellow | Potted-in cable with open end | |||
|
Cable diameter |
d |
mm |
6.5 | ||
|
Protection class according to DIN EN 60529 |
IP 65/IP 67 | ||||
|
Conformity |
According to EMC directive 2004/108/EG applied harmonized standards: EN 61000-6-2:2005, EN 61000-6-3:2007 | ||||
|
Ambient temperature range |
ϑ |
°C |
-20 … 60 | ||
|
Storage temperature range |
ϑ |
°C |
-20 … 60 | ||
|
Weight |
m |
g |
350 | ||
For applications outside these parameters, please consult us!
Switching times (with variant V001)
Comparison of 24 V coil (control standard 24 V signal) with 12 V coil (control viaVT-SSBA1-PWM-1X/V001…)
Additional valves on request.
If the connector switching amplifier is used, the power limit may be improved. The degree of improvement depends on the respective switching symbol of the valve.
Additional information on request.
Notice:
The specified switching times correspond to the time of signaling until a pressure change of 5 %. The switching times are specified for the same power limits as documented in data sheets 23178, 23340 and 23352 and for a horizontal installation position. The use of plug-in amplifiers V001 is not possible in connection with valves with amplified spring.|
Switching times for 5-4WE10…5X valves (5 chamber) |
Switching times for Z-4WE6…3X valves |
|||||||
|
Control spool |
Coil |
Switching time in ms |
Control spool |
Coil |
Switching time in ms |
|||
|
ON |
OFF |
ON |
OFF |
|||||
|
J2 |
24 V |
170 |
23 |
E63 |
24 V |
27 |
14 |
|
|
12 V at V001 |
44 |
12 V at V001 |
15 |
|||||
|
X84 |
24 V |
39 |
67 |
E68 |
24 V |
27 |
14 |
|
|
12 V at V001 |
20 |
12 V at V001 |
15 |
|||||
|
X250 |
24 V |
31 |
20 |
|||||
|
12 V at V001 |
16 |
|||||||
|
X252 |
24 V |
47 |
13 |
|||||
|
12 V at V001 |
17 |
|||||||
|
Switching times for 4WE10…5X valves (3 chamber) |
Switching times for 4WE6…6X valves |
|||||||
|
Control spool |
Coil |
Switching time in ms |
Control spool |
Coil |
Switching time in ms |
|||
|
ON |
OFF |
ON |
OFF |
|||||
|
C |
24 V |
58 |
48 |
C |
24 V |
27 |
14 |
|
|
12 V at V001 |
26 |
12 V at V001 |
17 |
|||||
|
D |
24 V |
78 |
28 |
D |
24 V |
42 |
11 |
|
|
12 V at V001 |
29 |
12 V at V001 |
25 |
|||||
|
E |
24 V |
55 |
35 |
E |
24 V |
32 |
11 |
|
|
12 V at V001 |
22 |
12 V at V001 |
22 |
|||||
|
E67 |
24 V |
84 |
31 |
E67 |
24 V |
39 |
12 |
|
|
12 V at V001 |
24 |
12 V at V001 |
21 |
|||||
|
J |
24 V |
63 |
51 |
G |
24 V |
33 |
11 |
|
|
12 V at V001 |
28 |
12 V at V001 |
28 |
|||||
|
J2 |
24 V |
47 |
31 |
J |
24 V |
37 |
17 |
|
|
12 V at V001 |
24 |
12 V at V001 |
17 |
|||||
|
Y |
24 V |
57 |
31 |
L |
24 V |
36 |
15 |
|
|
12 V at V001 |
23 |
12 V at V001 |
21 |
|||||
|
Y11 |
24 V |
46 |
50 |
M |
24 V |
47 |
26 |
|
|
12 V at V001 |
28 |
12 V at V001 |
33 |
|||||
|
X7 |
24 V |
62 |
13 |
|||||
|
12 V at V001 |
47 |
|||||||
Notice:
The use of plug-in amplifiers V002 is not possible in connection with valves with amplified spring. Reduction of the coil temperature by at least 30 KEnergy saving (with variant V002)
Energy saving with valves with 24 V coils using plug-in amplifier VT-SSBA1-PWM-1X/V002…
|
5-.WE (5-chamber version) |
Power consumption for Z-4WE6…3X valves |
|||||
|
Control spool |
Power in W at 24 V coil |
Power in W at 24 V coil with V002 |
Control spool |
Power in W at 24 V coil |
Power in W at 24 V coil with V002 |
|
|
J2 |
30 |
18 |
E63 |
30 |
18 |
|
|
X84 |
E68 |
|||||
|
X250 |
||||||
|
X252 |
||||||
|
Power consumption for 4WE10…5X valves (3 chamber) |
Power consumption for 4WE6…6X valves |
|||||
|
Control spool |
Power in W at 24 V coil |
Power in W at 24 V coil with V002 |
Control spool |
Power in W at 24 V coil |
Power in W at 24 V coil with V002 |
|
|
C |
40 |
24 |
C |
30 |
18 |
|
|
D |
D |
|||||
|
E |
E |
|||||
|
E67 |
E67 |
|||||
|
J |
G |
|||||
|
J2 |
J |
|||||
|
Y |
L |
|||||
|
Y11 |
M |
|||||
|
X7 |
||||||
Wire 2: enable "IN"
Wire 1: Operating voltage "+UB" (+24 V)
Wire 3: Operating voltage "GND"
Wire GNYE: Protective earth "PE"
4/2-way version
Dimensions in mm
Dimensions in mm
The connector switching amplifier may only operated in accordance with the limits and applications defined in the data sheet. Sufficient distance to radios and mobile phones is required (>> 1 m). In case of overload or short-circuit, the output is de-energized. Before switching it on again, enable signal "IN" has to be switched at "ON" (< 3.5 V). There is no galvanic isolation between the input and output. If used as power reducer, the power in PWM operation is not sufficient for repeated switching of the valve after exceeding the power limit in switched state. In case of an error, the temperature of the valve solenoid may increase. Take external monitoring measures to ensure that the maximum admissible surface temperature of the solenoid is complied with. The VT-SSBA1-PWM is no safety-relevant part of a control system according to EN ISO 13849-1:2006. To comply with safety requirements, the following points must be observed: In case the safety function is required, the voltage supply and the enable input of the VT-SSBA1-PWM is to be switched off by a suitable switching element with appropriate reliability. If persons have to enter the danger zone with activated VT-SSBA1-PWM, additional measures for guaranteeing their safety have to be taken for the reasons specified above.