You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

HYDRAFORCE
5003480P


$102.24 USD
  • HYDRAFORCE
  • Material:5003480P
  • Model:SP08-21-0-P-00 SOLENOID VALVE
  • Summary:SOLENOID PROPORTIONAL VALVE 2 PORT, 2 POSITION

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce 5003480P (5003480P) is a solenoid-operated, 2-port, normally open, poppet type proportional screw-in hydraulic cartridge valve. It is specifically designed for low leakage in load-holding applications. In its default state when de-energized, the SP0821 configuration of this model allows fluid flow from port 2 to port 1 while restricting flow from port 1 to port 2. The valve's operation can be adjusted by varying the level of electrical energy supplied to it; partial energization begins to throttle the flow from port 2 to port 1. Upon full energization, the valve's poppet closes against the seat effectively blocking any flow from port 2 to port 1. Conversely, flow from port 1 to port 2 is possible once the solenoid force is overcome. This model boasts several features enhancing its functionality and reliability in demanding applications. These include a continuous-duty rated coil and efficient wet-armature construction which ensure robust performance and durability. Additionally, it offers optional waterproof E-Coils that are rated up to IP69K for optimal protection against dust and moisture ingress, making it suitable for use in harsh environmental conditions. The compact size of the valve combined with an industry common cavity design facilitates easy installation and maintenance while ensuring compatibility with a wide range of hydraulic systems and components.

Materials: Steel with hardened work surface exposed surfaces plated per hf spec
plt033 for 960 hours of salt spray per ASTM b117-09 before corrosion (red
rust)

RatingsPressure Ratings
Pressure rating: 207 bar (3000 psi)

Flow Ratings
Maximum internal leakage: 5 drops/min
At 207 bar (3000 psi)

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With viton seals
-54 to 107 °C (-65 to 225 °F)
With polyurethane seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)
Electrical ParametersDither PWM frequency: 70 Hz
Minimum
Performancehttps://www.hydraforce.com/globalassets/product-images/sp08-21_perf_chrt2022-02-24.gif

Installation SpecificationsCavity:
08-size-2-way Cavities
Cartridge installation torque: 25.8 to 28.5 N-m (19 to 21 ft-lb)

Coil nut torque: 5.4 to 6.8 N-m (4 to 5 ft-lb)
Order CodePOSITION CODE DESCRIPTION SP08-21E-H-J-L E Manual Override E BLANK NONE E K Momentary Push Override, Knob E P Momentary Push Override, Button H Line Body H 0 No Body H 4T Aluminum SAE 4 H 6T Aluminum SAE 6 H 8T Aluminum SAE 8 H 6TD Ductile Iron SAE 6 H 8TD Ductile Iron SAE 8 H 2B Aluminum BSPP 1/4" (2) H 3B Aluminum BSPP 3/8" (3) H 3BD Ductile Iron BSPP 3/8" (3) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 10DL 10 VDC, D-Coil, Dual Lead Wires L 10DS 10 VDC, D-Coil, Dual Spade L 10EL 10 VDC, E-Coil, Dual Lead Wires, 18 inches long L 10EL/36 10 VDC, E-Coil, Dual Lead Wires, 36 inches long L 10ER 10 VDC, E-Coil, Deutsch L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires, 18 inches long L 12DL/36 12 VDC, D-Coil, Dual Lead Wires, 36 inches long L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DR 12 VDC, D-Coil, Deutsch L 12DS 12 VDC, D-Coil, Dual Spade L 12EG 12 VDC, E-Coil, DIN 43650 L 12EJ 12 VDC, E-Coil, AMP Jr. L 12EL 12 VDC, E-Coil, Dual Lead Wires, 18 inches long L 12EL/36 12 VDC, E-Coil, Dual Lead Wires, 36 inches long L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 20DG 20 VDC, D-Coil, DIN 43650 L 20DS 20 VDC, D-Coil, Dual Spade L 20ER 20 VDC, E-Coil, Deutsch L 24AG 24 VDC, D-Coil, DIN 43650 L 24AP 24 VDC, D-Coil, 1/2" Conduit and Dual Lead Wires L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires, 18 inches long L 24DL/36 24 VDC, D-Coil, Dual Lead Wires, 36 inches long L 24DL/W 24 VDC, D-Coil, Dual Lead Wires with Weatherpak L 24DR 24 VDC, D-Coil, Deutsch L 24DS 24 VDC, D-Coil, Dual Spade L 24EG 24 VDC, E-Coil, DIN 43650 L 24EJ 24 VDC, E-Coil, AMP Jr. L 24ER 24 VDC, E-Coil, Deutsch L 24EY 24 VDC, E-Coil, Metri-Pack 150 L 36DG 36 VDC, D-Coil, DIN 43650 L 36DS 36 VDC, D-Coil, Dual Spade
https://www.hydraforce.com/globalassets/product-images/sp08-21_dim_dwg2022-02-24.gif


Seal kit:
Seal kit installation instructions
Housings:
Available
08-2w valve bodies
Coils:
08 size D
coils
08 size E
coils