You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

HYDRAFORCE
5110500


$136.25 USD
  • HYDRAFORCE
  • Material:5110500
  • Model:PV08-30A-0-N-00 FLOW CONTROL
  • Summary:NORMALLY CLOSED PRESSURE COMPENSATED PROPORTIONAL FLOW REGULATOR

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce PV08-30A-0-N-00 (5110500) is a solenoid-operated, pressure-compensated, spool-type, normally closed, priority-type proportional flow control regulator. This versatile device can also function as a restrictive type, 2-way pressure-compensated proportional flow regulator when port 2 is blocked. The valve operates by regulating priority flow from port 1 to port 3, with the flow rate being proportional to the current applied to the solenoid. Excessive flow is bypassed through port 2 and can be utilized for auxiliary functions. It is crucial to avoid dead-heading of the priority line by external valving to prevent blocking of the bypass line. In restrictive mode applications, with port 2 blocked, the flow rate out of port 3 remains proportional to the current applied regardless of load pressure. Key features include excellent linearity and hysteresis characteristics, a hardened spool and cage for durability, optional coil voltages and terminations, and efficient wet-armature construction. The valve's pressure ratings include an inlet pressure of up to 241 bar (3500 psi), regulated and bypass pressures up to 207 bar (3000 psi), proof pressure at 345 bar (5000 psi), and burst pressure reaching up to 896 bar (13000 psi). Flow ratings vary based on configuration but can reach up to a maximum input of 22.8 lpm (6.0 gpm) when three-ported. Temperature ratings accommodate operating fluid temperatures from -40\u00b0C to 100\u00b0C with buna N seals or -26\u00b0C to 204\u00b0C with fluorocarbon seals. It supports hydraulic fluids with viscosities ranging from 7.4 to 420 cSt and maintains a maximum operating contamination level per ISO standards. The cartridge weight varies depending on specific configurations but ranges between approximately 0.15 kg (0.33 lb) and 0.27 kg (0.59 lb). The PV08-30A-0-N-00 ensures long-lasting performance with corrosion protection rated for up to 960 hours in salt spray conditions per ASTM B117 standards.

Cartridge weight: 0.15 kg (0.33 lb)
PV08-30A/30B
0.20 kg (0.45 lb)
PV08-30AM/30BM
0.27 kg (0.59 lb)
PV08-30AG/30BG

Internal wetted surface area: 155 cm² (24.1 in²)
PV08-30AM/30AG/30BM/30BG
152 cm² (23.6 in²)
PV08-30A/30B

Environmental
Corrosion protection: 960 hr salt spray per ASTM B117
GPV08-30XX

RatingsPressure Ratings
Pressure rating: 241 bar (3500 psi)
Inlet
207 bar (3000 psi)
Regulated and bypass

Proof pressure: 345 bar (5000 psi)

Burst pressure: 896 bar (13000 psi)

Flow Ratings
Flow rating: 11.4 lpm (3.0 gpm)
Flow range a, regulated, 2-ported
11.4 lpm (3.0 gpm)
Flow range a, regulated, 3-ported
5.7 lpm (1.5 gpm)
Flow range b, regulated, 2-ported
5.7 lpm (1.5 gpm)
Flow range b, regulated, 3-ported
15.2 lpm (4.0 gpm)
Flow range a, input nominal, 3-ported
7.6 lpm (2.0 gpm)
Flow range b, input nominal, 3-ported
22.8 lpm (6.0 gpm)
Flow range a, input maximum, 3-ported
22.8 lpm (6.0 gpm)
Flow range b, input maximum, 3-ported

Maximum internal leakage: 197 ml/min (12 in³/min)
At port 3 with at port 1 (port 2 closed) at 0 current 207 bar (3000
psi)

Hysteresis: ±0.9 lpm (±0.25 gpm)
Maximum

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)
Operating ParametersFluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 20/18/14 per ISO 4406 (reference all sheets)
Electrical ParametersNote: (With EHPR08 E-series and D-series coil)

Maximum control current: 1400 ±150 mA
12 V coil
700 ±75 mA
24 V coil

Threshold current: 400 ±100 mA
12 V coil
200 ±50 mA
24 V coil

Dither PWM frequency: 100 to 200 Hz
Performancehttps://www.hydraforce.com/globalassets/product-images/pv08-30_perf_chrt2022-02-24.gif

Installation SpecificationsCavity: VC08-3
08-size-3-way Cavities
Cartridge installation torque: 25.8 to 28.5 N-m (19 to 21 ft-lb

Maximum allowable torque: 47.5 N-m (35 ft-lb)

Coil nut torque: 6.8 to 9.5 N-m (5 to 7 ft-lb)
Coil nut and guard nut

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION PV08-30DE-H-J-L D Max Regulated Flow D A 11.4 lpm (3.0 gpm) Max Regulated Flow D B 5.7 lpm (1.5 gpm) Max Regulated Flow E Manual Override E BLANK NONE E G Variable Position Override, Red Knurled Knob with Cover Cap E M Variable Position Override, Red Knurled Knob H Line Body H 0 No Body H 4T Aluminum SAE 4 H 6T Aluminum SAE 6 H 6TD Ductile Iron SAE 6 H 8TD Ductile Iron SAE 8 H 3B Aluminum BSPP 3/8" (3) H 3BD Ductile Iron BSPP 3/8" (3) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 12DG 12 VDC, D-Coil, DIN 43650 L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DS 24 VDC, D-Coil, Dual Spade L 24ER 24 VDC, E-Coil, Deutsch
https://www.hydraforce.com/globalassets/product-images/pv08-30_dim_dwg2022-02-24.gif


Seal kit: SK08-3X-MM
X = seal option
Seal kit installation instructions
Housings:
Available
08-3w valve bodies
Coils:
EHPR size D
coils
EHPR size E
coils