***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce 5110510G (5110510G) is a solenoid-operated, pressure-compensated, spool-type, normally closed, priority-type proportional flow control regulator. This versatile component is designed to manage flow with precision and efficiency. It can also function as a restrictive type, 2-way, pressure-compensated proportional flow regulator when port 2 is blocked. The valve regulates priority flow from port 1 to port 3 consistently, regardless of system working pressure. The flow rate is directly proportional to the current applied to the solenoid. Any excess flow bypasses through port 2 and can be utilized for auxiliary function control. In applications where the restrictive mode is used, blocking bypass port 2 ensures that the flow rate out of port 3 remains proportional to the solenoid current, irrespective of the load or pressure at port 3. This model boasts excellent linearity and hysteresis characteristics due to its advanced design featuring a hardened spool and cage for enhanced durability and longevity. The PV08-30 offers optional coil voltages and terminations to suit various application needs and utilizes efficient wet-armature construction for optimal performance. For safe operation, it is crucial to avoid dead heading of the priority line by external valving to prevent blocking of the bypass line. This product's robust construction and adaptable features make it an ideal choice for applications requiring reliable flow regulation under varying pressures.

Cartridge weight: 0.15 kg (0.33 lb)
PV08-30A/30B
0.20 kg (0.45 lb)
PV08-30AM/30BM
0.27 kg (0.59 lb)
PV08-30AG/30BG

Internal wetted surface area: 155 cm² (24.1 in²)
PV08-30AM/30AG/30BM/30BG
152 cm² (23.6 in²)
PV08-30A/30B

Environmental
Corrosion protection: 960 hr salt spray per ASTM B117
GPV08-30XX

RatingsPressure Ratings
Pressure rating: 241 bar (3500 psi)
Inlet
207 bar (3000 psi)
Regulated and bypass

Proof pressure: 345 bar (5000 psi)

Burst pressure: 896 bar (13000 psi)

Flow Ratings
Flow rating: 11.4 lpm (3.0 gpm)
Flow range a, regulated, 2-ported
11.4 lpm (3.0 gpm)
Flow range a, regulated, 3-ported
5.7 lpm (1.5 gpm)
Flow range b, regulated, 2-ported
5.7 lpm (1.5 gpm)
Flow range b, regulated, 3-ported
15.2 lpm (4.0 gpm)
Flow range a, input nominal, 3-ported
7.6 lpm (2.0 gpm)
Flow range b, input nominal, 3-ported
22.8 lpm (6.0 gpm)
Flow range a, input maximum, 3-ported
22.8 lpm (6.0 gpm)
Flow range b, input maximum, 3-ported

Maximum internal leakage: 197 ml/min (12 in³/min)
At port 3 with at port 1 (port 2 closed) at 0 current 207 bar (3000
psi)

Hysteresis: ±0.9 lpm (±0.25 gpm)
Maximum

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)
Operating ParametersFluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 20/18/14 per ISO 4406 (reference all sheets)
Electrical ParametersNote: (With EHPR08 E-series and D-series coil)

Maximum control current: 1400 ±150 mA
12 V coil
700 ±75 mA
24 V coil

Threshold current: 400 ±100 mA
12 V coil
200 ±50 mA
24 V coil

Dither PWM frequency: 100 to 200 Hz
Performancehttps://www.hydraforce.com/globalassets/product-images/pv08-30_perf_chrt2022-02-24.gif

Installation SpecificationsCavity: VC08-3
08-size-3-way Cavities
Cartridge installation torque: 25.8 to 28.5 N-m (19 to 21 ft-lb

Maximum allowable torque: 47.5 N-m (35 ft-lb)

Coil nut torque: 6.8 to 9.5 N-m (5 to 7 ft-lb)
Coil nut and guard nut

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION PV08-30DE-H-J-L D Max Regulated Flow D A 11.4 lpm (3.0 gpm) Max Regulated Flow D B 5.7 lpm (1.5 gpm) Max Regulated Flow E Manual Override E BLANK NONE E G Variable Position Override, Red Knurled Knob with Cover Cap E M Variable Position Override, Red Knurled Knob H Line Body H 0 No Body H 4T Aluminum SAE 4 H 6T Aluminum SAE 6 H 6TD Ductile Iron SAE 6 H 8TD Ductile Iron SAE 8 H 3B Aluminum BSPP 3/8" (3) H 3BD Ductile Iron BSPP 3/8" (3) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 12DG 12 VDC, D-Coil, DIN 43650 L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DS 24 VDC, D-Coil, Dual Spade L 24ER 24 VDC, E-Coil, Deutsch
https://www.hydraforce.com/globalassets/product-images/pv08-30_dim_dwg2022-02-24.gif


Seal kit: SK08-3X-MM
X = seal option
Seal kit installation instructions
Housings:
Available
08-3w valve bodies
Coils:
EHPR size D
coils
EHPR size E
coils