HYDRAFORCE
5111029
$218.88 USD
- HYDRAFORCE
- Material:5111029
- Model:PV70-30A-0-N-24DS FLOW CONTROL
- Summary:NORMALLY CLOSED PRESSURE COMPENSATED PROPORTIONAL FLOW REGULATOR
Due to extremely high demand, please call 920-337-0234 for availability
The Hydraforce 5111029 (5111029) is a solenoid-operated, pressure-compensated, spool-type, normally closed, priority-type proportional flow control regulator. It offers versatility by also functioning as a restrictive type, 2-way, pressure-compensated proportional flow regulator when port 2 is blocked. Designed for applications requiring precise flow regulation, the valve ensures priority flow out of port 3 with inlet flow at port 1, irrespective of system working pressure. The flow rate is directly proportional to the current applied to the solenoid. Excessive flow bypasses through port 2 and can be utilized for auxiliary function control. To prevent blocking of the bypass line, it is important to avoid dead-heading of the priority line by external valving. In restrictive mode applications with port 2 blocked, the output at port 3 remains consistent with the solenoid current regardless of load pressure at port 3. This model features excellent linearity and hysteresis characteristics and is built for durability with a hardened spool and cage. It offers optional coil voltages and terminations and benefits from efficient wet-armature construction. The cartridges are voltage-interchangeable, enhancing flexibility in various settings. Its unitized molded coil design includes standard waterproofing for added reliability in challenging environments. Additionally, a manual override option provides further operational control when needed. This makes the Hydraforce 5111029 an adaptable solution for precise hydraulic control applications requiring robust performance and long service life.
Unit weight:
0.70 lb (0.32 kg)
PV70-30X
0.8 lb (0.37 kg)
Pv70-30mx
1.00 lb (0.45 kg)
Pv70-30gx
Internal wetted surface area:
202.2 cm² (31.3 in²)
PV70-30X
205.5 cm² (31.9 in²)
Pv70-30mx and pv70-30gx
| Ratings | Pressure Ratings Pressure rating: 241 bar (3500 psi) Inlet 207 bar (3000 psi) Regulated (port3) 207 bar (3000 psi) Proof pressure: 345 bar (5000 psi) Burst pressure: 896 bar (13000 psi) Flow Ratings Flow rating: 26.5 lpm (7.0 gpm) Regulated, range a, 2-ported 30.3 lpm (8.0 gpm) Regulated, range a, 3-ported 17.0 lpm (4.5 gpm) Regulated, range b, 2-ported 17.0 lpm (4.5 gpm) Regulated, range b, 3-ported 37.9 lpm (10.0 gpm) Nominal input, range a, 3-ported 18.9 lpm (5.0 gpm) Nominal input, range b, 3-ported 49.2 lpm (13.0 gpm) Maximum input, range a, 3-ported 26.5 lpm (7.0 gpm) Maximum input, range b, 3-ported Maximum internal leakage: 197 ml/min (12 in³/min) At port 3 with at port 1 (port 2 closed) 207 bar (3000 in³/min) Hysteresis per cent: % Maximum, regulated flow range of 30-90% Temperature Ratings Operating fluid temperature: -40 to 100 °C (-40 to 212 °F) With buna N seals -26 to 204 °C (-15 to 400 °F) With fluorocarbon seals -54 to 107 °C (-65 to 225 °F) With polyurethane seals Storage temperature: -40 to 70 °C (-40 to 160 °F) Ambient temperature: -40 to 70 °C (-40 to 160 °F) Other Ratings Corrosion protection: 960 hr salt spray per ASTM b117 |
| Operating Parameters | Fluids:
Mineral based or synthetic hydraulic fluid with lubricating properties Fluid viscosity range: 7.4 to 420 cSt Maximum operating contamination level: 18/16/13 per ISO 4406 |
| Electrical Parameters | Note:
(nominal values with size 70 e-series and d-series coil) Maximum control current: 1500 mA Coil, flow range A 12 V 1350 mA Coil, flow range b 12 V 750 mA Coil, flow range A 24 V 675 mA Coil, flow range b 24 V Threshold current: 335 mA Coil 12 V 165 mA Coil 24 V Valve inductance: 240 mH E-coil 12 V 200 mH D-coil 12 V 700 mH E-coil 24 V 600 mH D-coil 24 V Dither PWM frequency: 100 to 250 Hz |
| Performance | |
| Installation Specifications | Cavity:
VC10-3 10-size-3-way Cavities Cartridge installation torque: 33 to 35 N-m (24 to 26 ft-lb) Maximum allowable torque: 68 N-m (50 ft-lb) Coil nut torque: 14 to 16 N-m (10 to 12 ft-lb) Cover cap torque: 7 to 9 N-m (5 to 7 ft-lb) Orientation restriction: None |
| Order Code | POSITION CODE DESCRIPTION PV70-30DE-H-J-L D Max Regulated Flow D A 30.3 lpm (8.0 gpm) Max Regulated Flow D B 17.0 lpm (4.5 gpm) Max Regulated Flow E Manual Override E BLANK NONE E G Variable Position Override, Red Knurled Knob with Cover Cap E M Variable Position Override, Red Knurled Knob H Line Body H 0 No Body H 6T Aluminum SAE 6 H 8T Aluminum SAE 8 H 6TD Ductile Iron SAE 6 H 8TD Ductile Iron SAE 8 H 3B Aluminum BSPP 3/8" (3) H 3BD Ductile Iron BSPP 3/8" (3) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DS 12 VDC, D-Coil, Dual Spade L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DS 24 VDC, D-Coil, Dual Spade L 24ER 24 VDC, E-Coil, Deutsch |
Seal kit:
SK10-3X-MM
X = seal option
Seal kit installation instructions
Housings:
Available
10-3w valve bodies
Coils:
70 size D
coils
70 size E
coils
| Product ZIP File | Download Product ZIP File |