You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

HYDRAFORCE
5122944


$183.25 USD
  • HYDRAFORCE
  • Material:5122944
  • Model:TS12-27A-0-V-12ER PRESSURE CONTROL
  • Summary:Heavy-duty pressure sensor

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce 5122944 (5122944) is a high-accuracy, heavy-duty pressure sensor designed for demanding industrial and off-highway equipment applications. It achieves a total error band accuracy of 1% by integrating a high-performance ASIC with a stable, field-proven polysilicon thin-film pressure sensor. This robust sensor is engineered to deliver reliable performance within a temperature range of -20 to 85\u00b0C (-4 to 185\u00b0F), making it suitable for various challenging environments. The advanced ASIC technology ensures precision and reliability, while the sensor's design includes reverse polarity and miswire protection for enhanced safety in complex systems. Its broad temperature capability, combined with an all-welded pressure construction, makes it highly durable and suitable for long-term use in harsh conditions. Additionally, the Hydraforce 5122944 boasts a high EMI/RFI rating, ensuring that it operates effectively even in environments with significant electromagnetic interference. The IP67 ingress rating provides excellent protection against dust and water ingress, further enhancing its suitability for rugged applications. Furthermore, the sensor features diagnostic rails at 4.5 V, facilitating easy integration and monitoring within existing systems.

Unit weight: 0.25 kg (0.56 lb)

Internal wetted surface area: 244 cm² (37.8 in²)

RatingsPressure Ratings
Pressure rating: 275.8 bar (4000 psi)
Port 1
103.4 bar (1500 psi)
Port 2
103.4 bar (1500 psi)
Maximum tank port pressure dynamic condition

Proof pressure: 413.7 bar (6000 psi)
Port 1
206.8 bar (3000 psi)
Port 2

Burst pressure: 813.6 bar (11800 psi)

Pressure rise: 0.29 bar/lpm (16 psi/gpm)
A
0.24 bar/lpm (13 psi/gpm)
B
0.18 bar (10 psi/gpm)
C

Operating pressure range: 6.9 to 207 bar (100 to 3000 psi)
Tested at range A 7.5 lpm (2 gpm)
6.9 to 138 bar (100 to 2000 psi)
Tested at range b 7.5 lpm (2 gpm)
6.9 to 69 bar (100 to 1000 psi)
Tested at range c 7.5 lpm (2 gpm)

Note: Minimum pressure CAN be factory set to 6.2 to 10.3 bar (90 to 150
psi)

Flow Ratings
Flow rating: 189 lpm (50 gpm)
Delta-p (cartridge only) port 1-2 (coil de-energized) 15.1 to 18.9 bar
(220 to 275 psi)

Maximum pilot flow: 0.76 lpm (0.2 gpm)

Hysteresis per cent: 2.5 %
(a)
3.4 %
(b)
6 %
(c)

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F)
With polyurethane seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)

Other Ratings
Corrosion protection: 960 hr salt spray per ASTM b117
Operating ParametersFluids: Mineral based or synthetic with lubricating properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 18/16/13 per ISO 4406
Performancehttps://www.hydraforce.com/globalassets/product-images/ts12-27_perf_chrt12022-02-24.gif
https://www.hydraforce.com/globalassets/product-images/ts12-27_perf_chrt22022-02-24.gif

Installation SpecificationsCavity: VC12-2
12-size-2-way Cavities
Cartridge installation torque: 44.7 to 50.2 N-m (33 to 37 ft-lb)

Coil nut torque: 5.4 to 6.8 N-m (4 to 5 ft-lb)

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION TS12-27D-H-J-L D Regulating Pressure Range D A 206.8 to 6.9 bar (3000 to 100 psi) Pressure Range D B 137.9 to 6.9 bar (2000 to 100 psi) Pressure Range D C 68.9 to 6.9 bar (1000 to 100 psi) Pressure Range D F 248.2 to 55.2 bar (3600 to 800 psi) Crack Pressure at Zero Current H Line Body H 0 No Body H 10T Aluminum SAE 10 H 12T Aluminum SAE 12 H 16T Aluminum SAE 16 H 12TD Ductile Iron SAE 12 H 16TD Ductile Iron SAE 16 H 8B Aluminum BSPP 1" (8) H 8BD Ductile Iron BSPP 1" (8) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 10DG 10 VDC, D-Coil, DIN 43650 L 10DL 10 VDC, D-Coil, Dual Lead Wires L 10DS 10 VDC, D-Coil, Dual Spade L 10EL 10 VDC, E-Coil, Dual Lead Wires L 10ER 10 VDC, E-Coil, Deutsch L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires, 18 inches long L 12DL/36 12 VDC, D-Coil, Dual Lead Wires, 36 inches long L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DR 12 VDC, D-Coil, Deutsch L 12DS 12 VDC, D-Coil, Dual Spade L 12EG 12 VDC, E-Coil, DIN 43650 L 12EJ 12 VDC, E-Coil, AMP Jr. L 12EL 12 VDC, E-Coil, Dual Lead Wires, 18 inches long L 12EL/36 12 VDC, E-Coil, Dual Lead Wires, 36 inches long L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 20DS 20 VDC, D-Coil, Dual Spade L 20ER 20 VDC, E-Coil, Deutsch L 24AG 24 VDC, D-Coil, DIN 43650 L 24AP 24 VDC, D-Coil, 1/2" Conduit and Dual Lead Wires L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DL/W 24 VDC, D-Coil, Dual Lead Wires with Weatherpak L 24DP 24 VDC, D-Coil, 1/2" Conduit and Dual Lead Wires L 24DR 24 VDC, D-Coil, Deutsch L 24DS 24 VDC, D-Coil, Dual Spade L 24EG 24 VDC, E-Coil, DIN 43650 L 24EJ 24 VDC, E-Coil, AMP Jr. L 24EL 24 VDC, E-Coil, Dual Lead Wires, 18 inches long L 24EL/36 24 VDC, E-Coil, Dual Lead Wires, 36 inches long L 24ER 24 VDC, E-Coil, Deutsch L 24EY 24 VDC, E-Coil, Metri-Pack 150 L 36DS 36 VDC, D-Coil, Dual Spade
https://www.hydraforce.com/globalassets/product-images/ts12-27_dim_dwg2022-02-24.gif


Seal kit: SK12-2X-B
X = seal option
Seal kit installation instructions
Housings:
Available
12-2w valve bodies
Coils:
10 size D
coils
10 size E
coils