  • Material:5140308
  • Model:PV72-33AM-0-N-12DL/W SOLENOID COIL
  • Summary:NORMALLY CLOSED ELECTRO PROPORTIONAL VALVE CARTRIDGE

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce PV72-33AM-0-N-12DL/W (5140308) is a high-performance, solenoid-operated, spool-type, normally closed proportional flow control valve. This model offers precise control by regulating flow from port 3 to port 2 while keeping input from port 1 blocked. The valve's operation is directly proportional to the electric current applied to its solenoid, providing excellent linearity and hysteresis characteristics which make it highly effective in varied applications requiring precise flow management. This valve is designed for use with a pressure compensator and can handle a pressure differential of up to 175 psi (approximately 12 bar). It boasts robust construction with a hardened spool and cage ensuring long service life even under rigorous conditions. The PV72-33AM-0-N-12DL/W features optional control orifice sizes and coil voltages, allowing customization to meet specific system requirements. Its efficient wet-armature construction along with voltage-interchangeable cartridges enhances its versatility. Additional durability is provided through unitized, molded coil design and standard waterproofing of the coil, making it suitable for tough environmental conditions. A manual override option adds an extra layer of operational security and convenience. With such advanced specifications including a maximum flow rate of up to 15 GPM and various temperature ratings depending on the seal material used (ranging from -15°C up to 400°F with fluorocarbon seals), this valve is equipped to handle a wide array of hydraulic fluid types within a viscosity range of 7.4 to 420 cSt. Overall, the Hydraforce PV72-33AM-0-N-12DL/W offers robust performance for regulated flow applications in hydraulic systems, combining durability with adaptability in design to meet specific operational needs effectively.

Unit weight: 0.40 kg (0.88 lb)
Blank option
0.44 kg (0.98 lb)
"m" option
0.55 kg (1.21 lb)
"g" option

Internal wetted surface area: 283 cm² (43.8 in²)
Blank option
348 cm² (53.9 in²)
"m" option "g" option

RatingsPressure Ratings
Pressure rating: 240 bar (3500 psi)

Proof pressure: 345 bar (5000 psi)

Burst pressure: 896 bar (13000 psi)

Flow Ratings
Flow rating: 0 to 57 lpm (0 to 15.0 gpm)

Maximum internal leakage: 0.38 lpm (0.1 gpm)
Max at 100 current

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F)
With polyurethane seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)

Other Ratings
Corrosion protection: 960 hr salt spray per ASTM b117
Operating ParametersFluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 18/16/13 per ISO 4406
Electrical ParametersNote: With size 70 e-series and d-series coils

Maximum control current: 1500 mA
12 V coil
750 mA
24 V coil

Threshold current: 300 mA
12 V coil
150 mA
24 V coil

Valve inductance: 240 mH
E-coil 12 V
200 mH
D-coil 12 V
700 mH
E-coil 24 V
600 mH
E-coil 24 V

Dither PWM frequency: 100 to 250 Hz
Performancehttps://www.hydraforce.com/globalassets/product-images/pv72-33_perf_chrt2022-02-24.gif

Installation SpecificationsCavity: VC12-3
12-size-3-way Cavities
Cartridge installation torque: 47 N-m (35 ft-lb)

Coil nut torque: 14 to 16 N-m (10 to 12 ft-lb)

Cover cap torque: 7 to 9 N-m (5 to 7 ft-lb)

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION PV72-33DE-H-J-L D Max Regulated Flow D A 80.6 lpm (21.3 gpm) Max Regulated Flow D B 58.7 lpm (15.5 gpm) Max Regulated Flow E Manual Override E BLANK NONE E G Variable Position Override, Red Knurled Knob with Cover Cap E M Variable Position Override, Red Knurled Knob H Line Body H 0 No Body H 8T Aluminum SAE 8 H 10T Aluminum SAE 10 H 12T Aluminum SAE 12 H 12TD Ductile Iron SAE 12 H 6B Aluminum BSPP 3/4" (6) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DS 12 VDC, D-Coil, Dual Spade L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DS 24 VDC, D-Coil, Dual Spade L 24ER 24 VDC, E-Coil, Deutsch
https://www.hydraforce.com/globalassets/product-images/pv72-30_dim_dwg2022-02-24.gif


Seal kit: SK12-2X-M
X = seal option
Seal kit installation instructions
Housings:
Available
12-3w valve bodies
Coils:
70 size D
coils
70 size E
coils