You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

HYDRAFORCE
5142012


$366.70 USD
  • HYDRAFORCE
  • Material:5142012
  • Model:PV72-30A-12T-N-12DG FLOW CONTROL
  • Summary:NORMALLY CLOSED PRESSURE COMPENSATED ELECTRO-PROPORTIONAL PRIORITY FLOW REGULATOR VALVE CARTRIDGE

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce 5142012 (5142012) is a solenoid-operated, pressure-compensated, spool-type, normally closed, proportional priority flow control valve. This model, known as the PV7230, is designed to provide priority regulated flow at port 3 with both pressure compensated regulated and bypass flow. The regulated flow adjusts proportionally to the electric current applied to the solenoid, ensuring precise control in various applications. Key features of the Hydraforce 5142012 include a choice of two regulated flow ranges which enhance its adaptability for different system requirements. It boasts excellent linearity and hysteresis characteristics that promote consistent performance and reliability. The valve is equipped with optional coil voltages and terminations, allowing customization to meet specific operational needs. Constructed with efficient wet-armature construction, the 5142012 ensures durability and optimal functioning in demanding environments. Its cartridges are voltage-interchangeable which adds a layer of versatility for system integration. The unitized, molded coil design contributes to its robust structure while standard coil waterproofing enhances its suitability for use in moisture-prone conditions. Additionally, a manual override option is available providing auxiliary control if needed. This valve is particularly suited for applications requiring precise flow management where priority and bypass flows need to be balanced efficiently under varying pressure conditions. Its advanced features make it an ideal choice for sophisticated hydraulic systems looking for reliable and adjustable flow control solutions.

Unit weight: 0.42 kg (0.93 lb)
PV72-30X
0.47 kg (1.03 lb)
PV72-30XM
0.56 kg (1.23 lb)
PV72-30XG

Internal wetted surface area: 339 cm² (52.5 in²)
PV72-30X
342 cm² (53.0 in²)
PV72-30XM PV72-30XG

RatingsPressure Ratings
Pressure rating: 240 bar (3500 psi)

Proof pressure: 345 bar (5000 psi)

Burst pressure: 896 bar (13000 psi)

Flow Ratings
Flow rating: 0 to 57 lpm (0 to 15.0 gpm)
For "a" flow range;
0 to 38 lpm (0 to 10.0 gpm)
For "b" flow range

Maximum internal leakage: 0.38 lpm (0.1 gpm)
Max at 0 current

Hysteresis flow: lpm (gpm)

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F)
With polyurethane seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)

Other Ratings
Corrosion protection: 960 hr salt spray per ASTM b117
Operating ParametersFluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 18/16/13 per ISO 4406
Electrical ParametersNote: With size 70 e-series and d-series coils

Maximum control current: 1600 mA
12 V coil
800 mA
24 V coil

Threshold current: 350 mA
12 V coil
175 mA
24 V coil

Valve inductance: 240 mH
E-coil 12 V
200 mH
D-coil 12 V
700 mH
E-coil 12 V
600 mH
D-coil 24 V

Dither PWM frequency: 100 to 250 Hz
Performancehttps://www.hydraforce.com/globalassets/product-images/pv72-30_perf_chrt12022-02-24.gif
https://www.hydraforce.com/globalassets/product-images/pv72-30_perf_chrt22022-02-24.gif

Installation SpecificationsCavity: VC12-3
12-size-3-way Cavities
Cartridge installation torque: 45 to 50 N-m (33 to 37 ft-lb)

Maximum allowable torque: 68 N-m (50 ft-lb)

Coil nut torque: 14 to 16 N-m (10 to 12 ft-lb)

Cover cap torque: 7 to 9 N-m (5 to 7 ft-lb)

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION PV72-30DE-H-J-L D Max Regulated Flow D A 56.8 lpm (15.0 gpm) Max Regulated Flow D B 37.9 lpm (10.0 gpm) Max Regulated Flow E Manual Override E BLANK NONE E G Variable Position Override, Red Knurled Knob with Cover Cap E M Variable Position Override, Red Knurled Knob H Line Body H 0 No Body H 8T Aluminum SAE 8 H 10T Aluminum SAE 10 H 12T Aluminum SAE 12 H 12TD Ductile Iron SAE 12 H 6B Aluminum BSPP 3/4" (6) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DS 12 VDC, D-Coil, Dual Spade L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DS 24 VDC, D-Coil, Dual Spade L 24ER 24 VDC, E-Coil, Deutsch
https://www.hydraforce.com/globalassets/product-images/pv72-30_dim_rev122022-02-24.gif


Seal kit: SK12-3X-MM
X = seal option
Seal kit installation instructions
Housings:
Available
12-3w valve bodies
Coils:
70 size D
coils
70 size E
coils