You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

HYDRAFORCE
5142058


$250.45 USD
  • HYDRAFORCE
  • Material:5142058
  • Model:PV72-30A-0-N-12DL/W FLOW CONTROL
  • Summary:NORMALLY CLOSED PRESSURE COMPENSATED ELECTRO-PROPORTIONAL PRIORITY FLOW REGULATOR VALVE CARTRIDGE

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce PV72-30A-0-N-12DL/W (5142058) is a sophisticated solenoid-operated, pressure-compensated, spool-type, normally closed, proportional priority flow control valve. This valve is designed to provide priority regulated flow at port 3 with both pressure-compensated regulated and bypass flow. The regulated flow is directly proportional to the electric current applied to the solenoid, allowing for precise control over fluid handling in hydraulic systems. Key features of the PV72-30A-0-N-12DL/W include excellent linearity and hysteresis characteristics, a choice between two regulated flow ranges, and optional coil voltages and terminations. It boasts efficient wet-armature construction and cartridges that are voltage interchangeable. The unitized, molded coil design enhances durability and reliability in demanding environments. Additionally, this model comes standard with coil waterproofing and offers a manual override option for increased operational flexibility. This valve can handle pressures up to 240 bar (3500 psi) with a proof pressure of 345 bar (5000 psi) and a burst pressure of 896 bar (13000 psi). It supports fluid temperatures ranging from -40°C to 100°C (-40°F to 212°F) depending on seal material selection. Flow ratings vary from 0 to 57 liters per minute (0 to 15.0 gallons per minute), making it versatile for different hydraulic applications. The PV72-30A-0-N-12DL/W can be used with mineral-based or synthetic hydraulic fluids with lubricating properties within a viscosity range of 7.4 to 420 cSt. This valve also features exceptional corrosion protection enduring up to 960 hours of salt spray testing per ASTM B117 standards. It's suitable for various hydraulic applications where precise flow regulation is crucial under varying pressure conditions without compromising performance integrity.

Unit weight: 0.42 kg (0.93 lb)
PV72-30X
0.47 kg (1.03 lb)
PV72-30XM
0.56 kg (1.23 lb)
PV72-30XG

Internal wetted surface area: 339 cm² (52.5 in²)
PV72-30X
342 cm² (53.0 in²)
PV72-30XM PV72-30XG

RatingsPressure Ratings
Pressure rating: 240 bar (3500 psi)

Proof pressure: 345 bar (5000 psi)

Burst pressure: 896 bar (13000 psi)

Flow Ratings
Flow rating: 0 to 57 lpm (0 to 15.0 gpm)
For "a" flow range;
0 to 38 lpm (0 to 10.0 gpm)
For "b" flow range

Maximum internal leakage: 0.38 lpm (0.1 gpm)
Max at 0 current

Hysteresis flow: lpm (gpm)

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F)
With polyurethane seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)

Other Ratings
Corrosion protection: 960 hr salt spray per ASTM b117
Operating ParametersFluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 18/16/13 per ISO 4406
Electrical ParametersNote: With size 70 e-series and d-series coils

Maximum control current: 1600 mA
12 V coil
800 mA
24 V coil

Threshold current: 350 mA
12 V coil
175 mA
24 V coil

Valve inductance: 240 mH
E-coil 12 V
200 mH
D-coil 12 V
700 mH
E-coil 12 V
600 mH
D-coil 24 V

Dither PWM frequency: 100 to 250 Hz
Performancehttps://www.hydraforce.com/globalassets/product-images/pv72-30_perf_chrt12022-02-24.gif
https://www.hydraforce.com/globalassets/product-images/pv72-30_perf_chrt22022-02-24.gif

Installation SpecificationsCavity: VC12-3
12-size-3-way Cavities
Cartridge installation torque: 45 to 50 N-m (33 to 37 ft-lb)

Maximum allowable torque: 68 N-m (50 ft-lb)

Coil nut torque: 14 to 16 N-m (10 to 12 ft-lb)

Cover cap torque: 7 to 9 N-m (5 to 7 ft-lb)

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION PV72-30DE-H-J-L D Max Regulated Flow D A 56.8 lpm (15.0 gpm) Max Regulated Flow D B 37.9 lpm (10.0 gpm) Max Regulated Flow E Manual Override E BLANK NONE E G Variable Position Override, Red Knurled Knob with Cover Cap E M Variable Position Override, Red Knurled Knob H Line Body H 0 No Body H 8T Aluminum SAE 8 H 10T Aluminum SAE 10 H 12T Aluminum SAE 12 H 12TD Ductile Iron SAE 12 H 6B Aluminum BSPP 3/4" (6) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DS 12 VDC, D-Coil, Dual Spade L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DS 24 VDC, D-Coil, Dual Spade L 24ER 24 VDC, E-Coil, Deutsch
https://www.hydraforce.com/globalassets/product-images/pv72-30_dim_rev122022-02-24.gif


Seal kit: SK12-3X-MM
X = seal option
Seal kit installation instructions
Housings:
Available
12-3w valve bodies
Coils:
70 size D
coils
70 size E
coils