You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

HYDRAFORCE
5144036V


$238.83 USD
  • HYDRAFORCE
  • Material:5144036V
  • Model:PV72-20-0-V-24ER FLOW CONTROL
  • Summary:NORMALLY CLOSED PRESSURE COMPENSATED ELECTRO PROPORTIONAL FLOW REGULATOR VALVE CARTRIDGE

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce 5144036V (5144036V) is a solenoid-operated, two-port, pressure-compensated, spool type, normally closed, proportional flow control valve designed for precise fluid handling and control within hydraulic systems. The PV7220 model is engineered to maintain a regulated flow out of port 2, ensuring consistent performance regardless of variations in system working pressure. This valve responds to changes in electric current applied to the solenoid; as the current increases, so does the output flow from the valve. Key features of the 5144036V include a choice between two regulated flow ranges which allows for flexibility in application use. It boasts excellent linearity and hysteresis characteristics that enhance its reliability and accuracy in flow control. The durability of this model is heightened by its hardened spool and cage which are designed for extended operational life under rigorous conditions. Additionally, its efficient wet-armature construction contributes to its robust performance. The unitized molded coil design of this valve ensures waterproofing as a standard feature, making it suitable for various environments where moisture or direct water contact might be a concern. The 5144036V also offers optional coil voltages and terminations to accommodate different electrical requirements and connections for easier integration into existing systems. Moreover, cartridges are voltage-interchangeable which provides further adaptability and ease of maintenance. An optional manual override feature adds an extra layer of operational security allowing manual control when needed. This combination of advanced features makes the Hydraforce 5144036V an optimal choice for sophisticated hydraulic applications requiring precise flow management and durability.

Unit weight: 0.40 kg (0.88 lb)
Blank option
0.44 kg (0.98 lb)
"m" option
0.55 kg (1.21 lb)
"g" option

Internal wetted surface area: 283 cm² (43.8 in²)
Blank option
348 cm² (53.9 in²)
"m" option "g" option

RatingsPressure Ratings
Pressure rating: 240 bar (3500 psi)

Proof pressure: 345 bar (5000 psi)

Burst pressure: 896 bar (13000 psi)

Flow Ratings
Flow rating: 0 to 64.4 lpm (0 to 17.0 gpm)
For "a" flow range;
0 to 37.9 lpm (0 to 10.0 gpm)
For "b" flow range

Maximum internal leakage: 0.38 lpm (0.1 gpm)
Max at 0 current

Hysteresis flow: lpm (gpm)

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F)
With polyurethane seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)

Other Ratings
Corrosion protection: 960 hr salt spray per ASTM b117
Operating ParametersFluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 18/16/13 per ISO 4406
Electrical ParametersNote: With size 70 e-series and d-series coils

Maximum control current: 1500 mA
12 V coil
750 mA
24 V coil

Threshold current: 250 mA
12 V coil
125 mA
24 V coil

Valve inductance: 240 mH
E-coil 12 V
200 mH
D-coil 12 V
700 mH
E-coil 24 V
600 mH
D-coil 24 V

Dither PWM frequency: 100 to 250 Hz
Performancehttps://www.hydraforce.com/globalassets/product-images/pv72-20_perf_chrt2022-02-24.gif

Installation SpecificationsCavity: VC12-2B
12-size-2-way Cavities
Cartridge installation torque: 47 N-m (35 ft-lb)

Maximum allowable torque: 68 N-m (50 ft-lb)

Coil nut torque: 14 to 16 N-m (10 to 12 ft-lb)

Cover cap torque: 7 to 9 N-m (5 to 7 ft-lb)

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION PV72-20DE-H-J-L D Max Regulated Flow D A 64.4 lpm (17.0 gpm) Max Regulated Flow D B 37.9 lpm (10.0 gpm) Max Regulated Flow D BLANK 64.4 lpm (17.0 gpm) Max Regulated Flow E Manual Override E BLANK NONE E G Variable Position Override, Red Knurled Knob with Cover Cap E M Variable Position Override, Red Knurled Knob H Line Body H 0 No Body H 10T Aluminum SAE 10 H 12T Aluminum SAE 12 J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DS 12 VDC, D-Coil, Dual Spade L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DS 24 VDC, D-Coil, Dual Spade L 24ER 24 VDC, E-Coil, Deutsch
https://www.hydraforce.com/globalassets/product-images/pv72-20_dim_dwg2022-02-24.gif


Seal kit: SK12-2X-M
X = seal option
Seal kit installation instructions
Housings:
Available
12-2w valve bodies
Coils:
70 size D
coils
70 size E
coils