You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

HYDRAFORCE
5145204


$327.60 USD
  • HYDRAFORCE
  • Material:5145204
  • Model:PV76-30AM-0-N-24DG FLOW CONTROL
  • Summary:NORMALLY CLOSED PROPORTIONAL FLOW REGULATOR

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce 5145204 (5145204) is a sophisticated component designed for precise fluid handling in hydraulic systems. The Pv7630 model is a solenoid-operated, pressure-compensated, spool type, normally closed proportional flow control valve. This valve excels in applications where priority type flow regulation is necessary, offering pressure-compensated regulated and bypass flow. It can also function as a restrictive type, 2-way, pressure-compensated flow regulator when the bypass line port 2 is blocked. The performance of the Pv7630 is directly proportional to the electric current applied to its solenoid, allowing for fine-tuned control over the fluid flow. Key features of this valve include its excellent linearity and hysteresis characteristics which ensure consistent and reliable operation. The durability of the valve is enhanced by a hardened spool and cage, designed to withstand rigorous use over an extended period. Additionally, it offers flexibility in customization with optional coil voltages and terminations to suit various operational requirements. For maintenance or emergency manual control, an optional manual override feature is available. This feature adds an extra layer of operational security by allowing direct manual operation of the valve in case of electrical power failure or when adjustments are needed during system troubleshooting. The efficient wet-armature construction of the Pv7630 not only ensures its robustness but also enhances its performance efficiency, making it a valuable asset in complex hydraulic setups requiring precise flow management.

Unit weight: 0.6 kg (1.3 lb)
PV76-30A
0.64 kg (1.4 lb)
PV76-30AM
0.73 kg (1.6 lb)
PV76-30AG

Internal wetted surface area: 468 cm² (72.6 in²)
PV76-30A
473 cm² (73.3 in²)
PV76-30AM PV76-30AG

RatingsPressure Ratings
Pressure rating: 241 bar (3500 psi)
Inlet
207 bar (3000 psi)
Ports 2, 3

Proof pressure: 345 bar (5000 psi)

Burst pressure: 896 bar (13000 psi)

Flow Ratings
Flow rating: 85.2 lpm (22.5)
2-ported, regulated
94.6 lpm (25)
3-ported, regulated
121.1 lpm (32)
3-ported, input, nominal
151.4 lpm (40)
3-ported, input, maximum

Maximum internal leakage: 0.38 lpm (0.10 gpm)
At zero current

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals
-54 to 107 °C (-65 to 225 °F)
With polyurethane seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)

Other Ratings
Corrosion protection: 960 hr salt spray per ASTM b117
Operating ParametersFluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 18/16/14 per ISO 4406
Electrical ParametersMaximum control current: 1600 mA
12 V coil
800 mA
24 V coil

Threshold current: 300 mA
12 V coil
150 mA
24 V coil
Performancehttps://www.hydraforce.com/globalassets/product-images/pv76-30a_perf_chrt2022-02-24.gif

Installation SpecificationsCavity: VC16-3
16-size-3-way Cavities
Cartridge installation torque: 67.8 N-m (50 ft-lb)

Coil nut torque: 13.6 to 16.3 N-m (10 to 12 ft-lb)

Cover cap torque: 7 to 9 N-m (5 to 7 ft-lb)

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION PV76-30ADE-H-J-L D Max Regulated Flow D A 94.6 lpm (25.0 gpm) Max Regulated Flow E Manual Override E BLANK NONE E G Variable Position Override, Red Knurled Knob with Cover Cap E M Variable Position Override, Red Knurled Knob H Line Body H 0 No Body H 12T Aluminum SAE 12 H 16T Aluminum SAE 16 H 16TD Ductile Iron SAE 16 J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DS 12 VDC, D-Coil, Dual Spade L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DS 24 VDC, D-Coil, Dual Spade L 24ER 24 VDC, E-Coil, Deutsch
https://www.hydraforce.com/globalassets/product-images/pv76-30a_dim_dwg2022-02-24.gif


Seal kit: SK16-3X-MM
X = seal option
Seal kit installation instructions
Housings:
Available
16-3w valve bodies
Coils:
70 size D
coils
70 size E
coils