HYDRAFORCE
5164032


$243.32 USD
  • HYDRAFORCE
  • Material:5164032
  • Model:ZL70-30B-0-N-24ER FLOW CONTROLS
  • Summary:N.C. BIDIRECTIONAL FLOW REGULATOR U.S. PATENT No. 6,167,906

Due to extremely high demand, please call 920-337-0234 for availability

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce 5164032 (5164032) is a high-performance solenoid operated, pressure compensated, spool type, normally closed, proportional bidirectional flow control valve. Specifically designed for precise fluid control, the 5164032 regulates flow in both directions—either from port 2 to port 3 or vice versa—with the flow being directly proportional to the electric current applied to its solenoid. This model is particularly suitable for use with mineral-based or synthetic fluids that have lubricating properties. A standout feature of the Hydraforce 5164032 is its excellent linearity and hysteresis characteristics, which ensure smooth and consistent performance. The valve's construction includes a hardened spool and cage which significantly enhance its durability and lifespan. Additionally, it offers a choice of two regulated flow ranges, allowing for flexibility depending on specific application requirements. The valve also boasts an efficient wet-armature construction and comes with options for different coil voltages and terminations to suit various operational needs. For enhanced usability, it includes a manual override option. The body of the valve is crafted from aluminum, ensuring a lightweight yet robust structure. This model uses a 7814 UNF-2A thread type and specifies that it should not be used with E-coil outlines. The Hydraforce 5164032 is an ideal solution for applications requiring reliable bidirectional flow control in hydraulic systems.

Unit weight: 0.32 kg (0.70 lb)
ZL70-30X
0.37 kg (0.81 lb)
ZL70-30XM
0.45 kg (1.00 lb)
ZL70-30XG

Internal wetted surface area: 209.6 cm² (32.5 in²)
Zl7030x
212.8 cm² (33.0 in²)
Zl7030xm zl7030xg

RatingsPressure Ratings
Pressure rating: 241 bar (3500 psi)
Inlet (port 1)
207 bar (3000 psi)
Regulated (port 3)
207 bar (3000 psi)
Bypass (port 2)

Proof pressure: 689 bar (10000 psi)

Burst pressure: 1103 bar (16000 psi)

Flow Ratings
Flow rating: 0 to 20.1 lpm (0 to 5.3 gpm)
Flow range A
0 to 9.8 lpm (0 to 2.6 gpm)
Flow range b

Maximum internal leakage: 0.38 lpm (0.1 gpm)
Max at 0 current

Hysteresis flow: lpm (gpm)
Maximum

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With fluorocarbon seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)
Operating ParametersFluids: Mineral based or synthetic hydraulic fluid with lubricating
properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 18/16/13 per ISO 4406
Electrical ParametersMaximum control current: 1400 ±100 mA
12 V 70 Series D-coil
700 ±50 mA
24 V 70 Series D-coil
1400 ±100 mA
12 V 70 Series E-coil
700 ±50 mA
24 V 70 Series E-coil

Threshold current: 250 ±100 mA
12 V 70 Series D-coil
125 ±50 mA
24 V 70 Series D-coil
250 ±100 mA
12 V 70 Series E-coil
125 ±50 mA
24 V 70 Series E-coil

Valve inductance: 200 mH
12 V 70 Series D-coil
600 mH
24 V 70 Series D-coil
240 mH
12 V 70-Series E-coil
700 mH
24 V 70-Series E-coil

Dither PWM frequency: 100 to 250 Hz
Performancehttps://www.hydraforce.com/globalassets/product-images/zl70-30_perf_chrt2022-02-24.gif

Installation SpecificationsCavity: VC10-3
10-size-3-way Cavities
Cartridge installation torque: 34 to 37 N-m (25 to 27 ft-lb)

Coil nut torque: 14 to 16 N-m (10 to 12 ft-lb)

Cover cap torque: 7 to 9 N-m (5 to 7 ft-lb)

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION ZL70-30DE-H-J-L D Flow Range D A 0 to 21.1 lpm (0 to 5.3 gpm) Flow Range D B 0 to 9.8 lpm (0 to 2.6 gpm) Flow Range E Manual Override E BLANK NONE E G Variable Position Override, Red Knurled Knob with Cover Cap E M Variable Position Override, Red Knurled Knob H Line Body H 0 No Body H 6T Aluminum SAE 6 H 8T Aluminum SAE 8 H 6TD Ductile Iron SAE 6 H 8TD Ductile Iron SAE 8 H 3B Aluminum BSPP 3/8" (3) H 3BD Ductile Iron BSPP 3/8" (3) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane L Coil L 0 No Coil L 12DG 12 VDC, D-Coil, DIN 43650 L 12DL 12 VDC, D-Coil, Dual Lead Wires L 12DL/W 12 VDC, D-Coil, Dual Lead Wires with Weatherpak L 12DS 12 VDC, D-Coil, Dual Spade L 12ER 12 VDC, E-Coil, Deutsch L 12EY 12 VDC, E-Coil, Metri-Pack 150 L 24DG 24 VDC, D-Coil, DIN 43650 L 24DL 24 VDC, D-Coil, Dual Lead Wires L 24DS 24 VDC, D-Coil, Dual Spade L 24ER 24 VDC, E-Coil, Deutsch
https://www.hydraforce.com/globalassets/product-images/zl70-30_dim_dwg2022-02-24.gif


Seal kit: SK10-3X-MM
X = seal option
Seal kit installation instructions
Housings:
Available
10-3w valve bodies
Coils:
70 size D
coils
70 size E
coils