HYDRAFORCE
5270202
$46.23 USD
- HYDRAFORCE
- Material:5270202
- Model:MV08-22-0-P MANUAL RELEASE VALVE
- Summary:MANUAL RELEASE VALVE
Due to extremely high demand, please call 920-337-0234 for availability
The Hydraforce 5270202 (5270202) is a screw-in, cartridge-style, cam-operated, two-way normally closed, poppet type directional valve designed for precise control in hydraulic systems. The model MV0822 operates by blocking flow from port 2 to port 1 until an applied cam force overcomes the spring bias and load force. This valve features a hardened seat and poppet to ensure durability and a long service life, enhancing its reliability in various applications. Additionally, the inclusion of a stainless steel cam button contributes to its robust construction and resistance to wear. Its compact size allows for easier integration into tight spaces within hydraulic circuits without sacrificing performance. The Hydraforce 5270202 is particularly suitable for use in systems where space is at a premium but effective flow control is essential.
Operating force required:
9.1 kg (20 lbf)
With no load at port 2
20.9 kg (46 lbf)
With port 2 loaded at 69 bar (1000 psi)
32.7 kg (72 lbf)
With port 2 loaded at 138 bar (2000 psi)
44.5 kg (98 lbf)
With port 2 loaded at 207 bar (3000 psi)
Unit weight:
0.08 kg (0.2 lb)
Internal wetted surface area:
64 cm² (9.9 in²)
| Ratings | Pressure Ratings Pressure rating: 207 bar (3000 psi) Flow Ratings Flow rating: 37.9 lpm (10 gpm) Maximum internal leakage: 0.15 ml/min (3 drops/min) At port 2 20.7 to 207 bar (300 to 3000 psi) Temperature Ratings Operating fluid temperature: -40 to 100 °C (-40 to 212 °F) With buna N seals -26 to 204 °C (-15 to 400 °F) With fluorocarbon seals -54 to 107 °C (-65 to 225 °F) With polyurethane seals Storage temperature: -40 to 70 °C (-40 to 160 °F) Ambient temperature: -40 to 70 °C (-40 to 160 °F) Other Ratings Corrosion protection: 960 hr salt spray per ASTM b117 (gmv08-22) |
| Operating Parameters | Fluids:
Mineral based or synthetic hydraulic fluid with lubricating properties Fluid viscosity range: 7.4 to 420 cSt Maximum operating contamination level: 20/18/14 per ISO 4406 |
| Performance | |
| Installation Specifications | Cavity:
VC08-2A 08-size-2-way Cavities Cartridge installation torque: 24.4 to 27.2 N-m (18 to 20 ft-lb) Orientation restriction: None |
| Order Code | POSITION CODE DESCRIPTION MV08-22-H-J H Line Body H 0 No Body H 6T Aluminum SAE 6 H 8T Aluminum SAE 8 H 6TD Ductile Iron SAE 6 H 8TD Ductile Iron SAE 8 H 2B Aluminum BSPP 1/4" (2) H 3B Aluminum BSPP 3/8" (3) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane |
Seal kit:
SK08-2X-T
X = seal option
Seal kit installation instructions
Housings:
Available
08-2w valve bodies
| Product ZIP File | Download Product ZIP File |
| Product PDF File | Download Product PDF File |