HYDRAFORCE
5283012
$73.45 USD
- HYDRAFORCE
- Material:5283012
- Model:EP12-S35M-0-P-80 LOGIC ELEMENT
- Summary:DIRECTIONAL ELEMENT, PILOTED
Due to extremely high demand, please call 920-337-0234 for availability
The Hydraforce 5283012 (5283012) is a screw-in, cartridge-style, pilot-to-close hydraulic directional element designed for advanced fluid control in hydraulic systems. This model operates as a spring-biased blocking valve, which shifts to permit full flow from port 1 to port 2 only when the pressure at port 1 surpasses the combined pressure at port 3 plus the bias spring pressure. The valve's design ensures a low pressure drop across its operation, enhancing system efficiency and performance reliability. It features an industry-common cavity that allows for broad compatibility and interchangeability with existing system configurations. Additionally, the EP12S35XX model offers a manual override option equipped with an 80 psi spring, providing auxiliary control in various application scenarios. This flexibility makes it suitable for multiple function applications across different hydraulic systems where precise flow regulation is critical.
Unit weight:
0.28 kg (0.61 lb)
EP12-S35
0.44 kg (0.97 lb)
EP12-S35T
0.31 kg (0.69 lb)
EP12-S35M
Internal wetted surface area:
207 cm² (32.15 in²)
EP12-S35
269 cm² (41.63 in²)
EP12-S35T
190 cm² (29.52 in²)
EP12-S35M
| Ratings | Pressure Ratings Pressure rating: 345 bar (5000 psi) Flow Ratings Flow rating: See performance graph Maximum internal leakage: 131 ml/min (8 in³/min) At 345 bar (5000 psi) Temperature Ratings Operating fluid temperature: -40 to 100 °C (-40 to 212 °F) With buna N seals -26 to 204 °C (-15 to 400 °F) With fluorocarbon seals -26 to 204 °C (-15 to 400 °F) With high durometer fluorocarbon seals -54 to 107 °C (-65 to 225 °F) With polyurethane seals Storage temperature: -40 to 70 °C (-40 to 160 °F) Ambient temperature: -40 to 90 °C (-40 to 194 °F) |
| Operating Parameters | Fluids:
Mineral based or synthetic hydraulic fluid with lubricating properties Fluid viscosity range: 7.4 to 420 cSt Maximum operating contamination level: 20/18/14 per ISO 4406 |
| Performance | |
| Installation Specifications | Cavity:
VC12-S3 12-size-3-way Cavities Cartridge installation torque: 44.7 to 50.2 N-m (33 to 37 ft-lb) Orientation restriction: None |
| Order Code | POSITION CODE DESCRIPTION EP12-S35CDF-H-J-R C Adaptor Option C BLANK Standard Cap C T Tall Cap D Cage Option D BLANK Standard Cage D G Metering (staggered holes) F Stroke Limiter F BLANK Standard F M Stroke Limiter H Line Body H 0 No Body H 12T Aluminum SAE 12 H 12TD Ductile Iron SAE 12 H 6BD Ductile Iron BSPP 3/4" (6) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane R Spring R 10 10 psi Bias Spring R 40 40 psi Bias Spring R 80 80 psi Bias Spring R 100 100 psi Bias Spring R 160 160 psi Bias Spring R 240 240 psi Bias Spring |
Seal kit:
SK12-S3X-MM
X = seal option
Seal kit installation instructions
Housings:
Available
12-3w valve bodies
| Product ZIP File | Download Product ZIP File |