***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Hydraforce directly.***
The Hydraforce 5616444 (5616444) is a screw-in, cartridge-style, direct-acting spool type hydraulic pressure reducing/relieving valve. Designed with an internal pilot and internal spring chamber drain, this valve is suitable for secondary circuits in stable input flow applications. In its steady state, the PR10-32X model permits bidirectional flow from port 2 to port 1 while maintaining a constant drain of the spring chamber at port 3. Upon reaching a predetermined pressure at port 1, the valve shifts to block flow at port 2, effectively regulating pressure at port 1. Additionally, it can relieve pressure from port 1 to port 3 over a variable range above the set reducing pressure. Notable features include adjustments that cannot be backed out of the valve and prevent springs from going solid. It offers optional spring ranges up to 145 bar (2100 psi) and incorporates a hardened spool and cage for extended durability. The PR10-32X's industry-common size ensures compatibility with various systems requiring precise pressure regulation and relief functions.

Unit weight: 0.25 kg (0.56 lb)
PR10-32A
0.29 kg (0.65 lb)
Pr10-32c/l
0.28 kg (0.61 lb)
PR10-32B
0.24 kg (0.54 lb)
Pr10-32f/h

Internal wetted surface area: 148 cm² (22.9 in²)
Pr10-32a/b/c/l
163 cm² (25.2 in²)
Pr10-32f/h

RatingsPressure Ratings
Pressure rating: 206.8 bar (3000 psi)
Port 1
206.8 bar (3000 psi)
Port 2
68.9 bar (1000 psi)
Port 3

Proof pressure: 517.1 bar (7500 psi)
Port 1
517.1 bar (7500 psi)
Port 2
103.4 bar (1500 psi)
Port 3

Burst pressure: 1034 bar (15000 psi)

Crack pressure defined: Pressure evident at 0.95 lpm (0.25 gpm) attained port 1 to port
2

Flow Ratings
Flow rating: 30.3 lpm (8 gpm)

Maximum internal leakage: 82 ml/min (5 in³/min)
Port 2 to 3 at 206.8 bar (3000 psi)

Temperature Ratings
Operating fluid temperature: -40 to 100 °C (-40 to 212 °F)
With buna N seals
-26 to 204 °C (-15 to 400 °F)
With viton seals
-54 to 107 °C (-65 to 225 °F)
With polyurethane seals

Storage temperature: -40 to 70 °C (-40 to 160 °F)

Ambient temperature: -40 to 70 °C (-40 to 160 °F)
Operating ParametersFluids: Mineral based or synthetic with lubricating properties

Fluid viscosity range: 7.4 to 420 cSt

Maximum operating contamination level: 18/16/13 per ISO 4406
Performancehttps://www.hydraforce.com/globalassets/product-images/pr10-32_flow-pressure2022-02-24.gif

Installation SpecificationsCavity: VC10-3
10-size-3-way Cavities
Cartridge installation torque: 32.5 to 35.3 N-m (24 to 26 ft-lb)

H style plug torque: 33.9 N-m (25 ft-lb)

Orientation restriction: None
Order CodePOSITION CODE DESCRIPTION PR10-32F-H-J-R/S F Adjustment Option F A 1/4" Hex Allen Head F B 1-1/2" Diameter Aluminum Knob with Aluminum Lock Knob F C 1/4" Hex Allen Head with Cover Cap F F Factory Preset Non-Adjustable F H Factory Preset Hidden Adjustment F L 1/4" Hex Allen Head with Cover Cap and Lockwire Holes H Line Body H 0 No Body H 6T Aluminum SAE 6 H 8T Aluminum SAE 8 H 6TD Ductile Iron SAE 6 H 8TD Ductile Iron SAE 8 H 3B Aluminum BSPP 3/8" (3) H 3BD Ductile Iron BSPP 3/8" (3) J Seal J N Buna-N J V Fluorocarbon J P Polyurethane J U PPDI Urethane R Spring R 01 2.4 to 8.6 bar (35 to 125 psi) Spring Range R 04 5.5 to 27.6 bar (80 to 400 psi) Spring Range R 08 13.8 to 55.2 bar (200 to 800 psi) Spring Range R 15 20.7 to 103.4 bar (300 to 1500 psi) Spring Range R 21 27.6 to 144.8 bar (400 to 2100 psi) Spring Range S Setting S MXXX Spring Setting in XXX bar S XX Spring Setting in XX psi (x 100)
https://www.hydraforce.com/globalassets/product-images/pr10-32_dim2022-02-24.gif


Seal kit: SK10-3X-BM
X = seal option
Seal kit installation instructions
Housings:
Available
10-3w valve bodies